Technical Data; Reproducibility; Particle Size; Viscosity - ProMinent Hydro/ 4 Assembly And Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

Technical data

10
Technical data
Only with "M - modified" design:
10.1

Reproducibility

Specification
Standard performance test
API test complete
* with measurements taken under constant conditions, minimum 10 % stroke length (and/or stroke volume) and water
at a temperature of 20 °C - when installed correctly and with a back pressure of at least 1 bar
10.2

Particle size

10.3

Viscosity

Tab. 6: The liquid ends are generally suitable for the following viscosity ranges:
Design
without valve springs - DN15 and DN25 only
with valve springs
* Only when the installation is correctly adjusted.
48
Always note the technical data on the nameplate and on
the pump data sheet as a priority.
Their information has priority over the information given
in this chapter.
Please observe the "Supplementary information for
modified version" at the end of the chapter.
It replaces and supplements the technical data.
Value
±1 % *
±1 % *
Make sure that the particle size in the feed chemical does not exceed 0.3
mm.
Range
Unit
0 ... 200
mPas
200 ... 500
mPas