D564)N (Select Measurement Units); D565)N (Select Speed Units); D566)N (Select Temperature Units); D567)Filename (Select Power-Up Script) - Microcom LDS2 Programming Manual

Table of Contents

Advertisement

Chapter 2
action that has just resulted from a command, and listings of printer parameters, where the
listed values are each identified by descriptive text. This mode is very helpful when learning
how to use the printer for the first time and is not intended to be used for actual
programming.
1
Text (Default)
2
Byte
9
Verbose
2.4.8
^D564)n
This command used to select the prevailing unit of measure the printer will use. Some
commands and/or calculations use a constant unit of measure and will not change with the
issuance of this command. These commands and/or calculations that use a constant unit of
measure are noted in their respective descriptions. This command is always the first
command to be processed by the printer regardless of the placement within a script. This is
helpful in forcing a unit of measure for troubleshooting and support capabilities.
1
Inches
2
Millimeters
2.4.9
^D565)n
This command used to select the desired unit of measure used for the speed parameter.
This command is independent from the "^D564)" command. The valid selections for the "n"
parameter are listed below with the default being a "1" (Inches). This command is always
processed first in a script or just after the "^D564)" command by the printer regardless of the
placement within a script. This is helpful in forcing a unit of measure for troubleshooting and
support capabilities.
1
Inches per Second (ips)
2
Centimeters per Second (cm/sec)
2.4.10
^D566)n
The "^D566)" command is used to select the temperature unit of measure the printer will
use for displaying the print head temperatures in degrees. This command is always
processed first in a script or just after the "^D564)" and "^D565)" commands by the printer
regardless of the placement within a script. This is helpful in forcing a unit of measure for
troubleshooting and support capabilities.
1
Fahrenheit
2
Centigrade
2.4.11
^D567)filename
The "^D567)" command is used to select the script that is processed on a printer power-up.
It is used in conjunction with the "^D720)" command to automatically process the selected
script on a power-up. Issuing the "^D567)" without a parameter builds and lists the scripts
that have been saved into the printers flash memory. The filename may contain to a
maximum of 20 characters in length and include any character from ASCII 0x20 and 0x41 to
0x7A (alphabetical characters plus [\]_'and SP (space character)) with the exception of the
caret (^) character. Script filenames can not use a leading zero ("0") or 0x30 characters.
2-14
(Select Measurement Units)
(Select Speed Units)
(Select Temperature Units)
(Select Power-up Script)
LDS2 Programming Manual - 880019-0202
Printer Commands