After Use

The last residual pressure warning
is generated when the pressure
reaches to approx. 10 bar.
Alarm:
Intermittent bleep,
continuous
Red LEDs:
Flash constantly.
Approx. 95 % of the oxygen in the
cylinder have now been consumed.
DANGER
The mission must be ended and
PSS BG 4 taken off when the pressure
reaches 10 bar.
This must be done in a safe environ-
ment (see "Use" on page 31).
After Use
Unplug the breathing hoses from the
mask:
1 Press the button and
2 pull out the plug-in coupling.
Immediately after pull out the plug-in
coupling close the cylinder valve.
The air is automatically let out of the
breathing circuit.
Switching Off Bodyguard
Simultaneously press the right and
left hand button until a single sharp
audible "Bleep" sounds.
Release buttons.
— For 3 seconds Bodyguard shows the
battery status.
— Bodyguard switches off.
36
bar
1
2
bar
1x Bleep
bar
После использования
Последний предупредительный
сигнал о низком остаточном
давлении подается, когда
давление достигает примерно
10 бар.
Прерывистый
Сигнал:
звуковой сигнал,
непрерывный
Красные СД: Непрерывно
мигают.
К этому моменту израсходовано
приблизительно 95 %
кислорода в баллоне.
ОПАСНО
Закончите работы и снимите
PSS BG 4, когда давление упадет
до 10 бар.
Это должно выполняться в
безопасной среде (см.
"Использование" на стр. 31).
После
использования
Отсоедините дыхательные шланги
от маски:
1 Нажмите кнопку и
2 выньте штекерный соединитель.
Немедленно после того, вынут
штекерный соединитель, закройте
вентиль баллона.
Воздух автоматически стравится
из дыхательного контура.
Выключение Bodyguard
Одновременно нажмите и
удерживайте правую и левую
кнопки, пока прибор не подаст
однократный резкий звуковой
сигнал.
Отпустите кнопки.
– В течение 3-х секунд Bodyguard
показывает состояние батареи.
– Bodyguard выключается.