Dräger PSS BG 4 Manual page 44

Hide thumbs Also See for PSS BG 4:
Table of Contents

Advertisement

Maintenance and Care
Removing the Relief Valve
1 Hold the relief valve by its hose con-
nector and swing it approx. 45
right.
2 Press the clamps together until they
disengage.
Remove the relief valve.
Dismantling the Relief Valve
3 Remove the valve cover.
4 Detach the stepped valve disk from
the valve cover.
5 Remove the valve disk.
Dismounting the Lever
6 Lift the safety knob and pull the lever
off to the right.
7 Lift the safety knob and pull off the
lever.
Removing the Switch Box
Use a screw driver to unlatch the
switch box from the holder.
Pull the switch box out of the holder
and put it down. Do not detach the
electrical couplings.
44
o
to the
Техническое и сервисное
обслуживание
Отсоединение
избыточного клапана
1 Возьмите избыточный клапан за
2 Нажмите на защелки, сводя их
1
2
Разборка избыточного
клапана
3 Снимите крышку клапана.
4
4 Отсоедините профилированный
5 Снимите диск клапана.
3
5
Отсоединение рычага
6 Снимите фиксирующую кнопку и
7 Снимите фиксирующую кнопку и
6
7
Отсоединение
кислородно-
распределительной
коробки
его соединитель шланга и
поверните приблизительно на 45
вправо.
вместе, пока они не освободятся.
Снимите предохранительный
клапан.
диск клапана от крышки клапана.
потяните рычаг направо.
выньте рычаг.
Отверткой освободите
кислородно-распределительную
коробку из держателя.
Вытяните кислородно-
распределительную коробку из
держателя и положите вниз. Не
снимайте электрические
соединения.
o

Advertisement

Table of Contents
loading

Table of Contents