Download Print this page

Faro Gage Training Workbook page 68

Hide thumbs Also See for Gage:

Advertisement

Basic Training Workbook
Version 1.5 - August 2007
9 View the results of your dimension.
10 Type Nominal Length = 65 and Tolerance = +/-0.25.
11 Select OK to add the dimension to your FARO Gage part file.
GD&T (Optional)
Let's check the Position of the 20mm holes. Use the Position command to measure the GD&T
Position of an existing feature. Position measures a feature RFS (Regardless of Feature Size)
and MMC (Maximum Material Condition).
1 Select the DIMENSIONS
drawer in the Toolbox.
2 Select the GD&T group.
3 Select the Position command.
4 Select the RUN button.
5 Type a name for your dimension, or use the default name.
Chapter 4: Basic Part Measurements (Metrology Mode)
58

Advertisement

loading