Version 1.5 - August 2007
6 Measure the center hole with the FARO Gage.
7 View the results of your measurement in the R
8 Type Nominal diameter = 20 and Tolerance = +0.25, -0.10.
Chapter 4: Basic Part Measurements (Metrology Mode)
Place the ball probe on the part and digitize points with the GREEN button.
Digitize 3 or more points in the hole.
Pull away from the hole edge and digitize 1 point with the RED button to complete
the command.
dialog box.
ESULTS
54

Advertisement