Setting the TX Noise Cancel level
<Key operation> (Continued)
Mobile: For the Segment types
1� Turn OFF the transceiver�
2� While holding down [F2] and [F3], turn ON the
transceiver� Continue holding down [F2] and [F3]
for about 3 seconds�
• 2 beeps sound�
3� Hold down [F1] for 1 second to enter the Set
mode�
4� Push [F2] or [F3] to select "A7�"
5� Push [Up] to increase, or push [Down] to decrease
the TX Noise Cancel level�
InoormaioI
L
• The setable range is 1 ~ 3, or OFF�
• When "OFF" is selected, the microphone input noise is
not suppressed�
• A beep sounds after pushing [Up] or [Down]� An error
beep sounds if you try to exceed the setable range�
3
2
1
OFF
6� Hold down [F1] for 1 second to exit the Set mode�
7� Turn OFF the transceiver, then turn it ON again to
normally operate it�
F1
F2
[F1] [F2] [F3]
: Push [Up]
: Push [Down]
[Up]
F3
[Down]
Power key