ADVANCED OPERATION
Emergency call
D Transmitting an Emergency call (Continued)
The transceiver enters the Emergency mode through
the following functions:
• The Man Down function
When the transceiver leans past the preset angle for
the ON Timer preset time�
L If a user raises the transceiver back from the preset
angle towards the vertical position before the
Reminder Timer set time expires, the Emergency
mode is canceled�
(Example)
• ON Timer:
10 seconds
• Reminder Timer: 10 seconds
• Angle:
45 degrees
Enters the
Emergency mode.
10 sec.
ON Timer
Pasts 45 degrees
Sends an
Emergency call.
10 sec.
Reminder
Emergency
Timer
Timer
Time
With Stationary
z The transceiver leans past the preset angle for the
ON Timer preset time�
AND
z The transceiver is detected as stationary (no
motion) for the ON Timer set time�
L If a user raises the transceiver back from the preset
angle towards the vertical position, or when the
user moves the transceiver before the Reminder
Timer set time expires, the Emergency mode is
canceled�
(Example)
• ON Timer:
• Reminder Timer: 10 seconds
• Angle:
Enters the
Emergency mode.
10 sec.
ON Timer
No motion is
detected.
Pasts 45 degrees
4-4
10 seconds
45 degrees
Sends an
Emergency call.
10 sec.
Reminder
Emergency
Timer
Timer
Time
Stationary
Sensitivity