Chapter 8: Verifying the Status of VCStack
94
awplus(config)# exit
awplus#
Figure 53. Returning to the Privileged Exec Mode with the EXIT Command
6. Enter the WRITE command to save your change, as shown in
Figure 54.
awplus# write
Building configuration ...
[OK]
awplus#
Figure 54. Saving the Change with the WRITE Command
Note
If this is the initial management session of the switch, the WRITE
command automatically creates in flash memory a new
configuration file called DEFAULT.CFG in which it stores your
configuration change. You may change the name of the file or
designate a different file after you create the stack.
7. Restart the switch with the REBOOT command, as shown in
Figure 55.
awplus# reboot
reboot system? (y/n):
awplus#
Figure 55. Rebooting the Switch with the REBOOT Command
8. Type "Y" for yes.
9. Wait one minute for the switch to initialize its management software.
10. Check the ID LED and do one of the following:
If the ID LED is displaying the number 1, 2, 3, or 4, VCStack is now
enabled on the switch. Power off the DC circuit and repeat the
procedures in this chapter on the next switch. If there are no further
switches to test, go to Chapter 9, "Cabling the Stacking Ports" on
page 95.
If the ID LED is still displaying "0," repeat this procedure. If the
procedure was not successful, it might be because you did not
issue the WRITE command in Step 6 to save your change.