Figure 69: Returning To The Privileged Exec Mode; Figure 70: Saving The Priority Values With The Write Command; Figure 71: Show Stack Command With New Switch Priority Values - Allied Telesis x330-52GTX Installation Manual

Fanless gigabit layer 3 access switches for virtual chassis stacking
Table of Contents

Advertisement

awplus# show stack
Virtual Chassis Stacking summary information
ID
Pending ID
1
-
2
-
3
-
4
-
Operational Status
Stack MAC address
To assign the priority value to 2 to the switch with the ID number 2, you
enter:
awplus(config)# stack 2 priority 2
6. After setting the priority values, enter the EXIT command to return to
the Privileged Exec mode. Refer to Figure 69.
awplus(config)# exit
awplus#
Figure 69. Returning to the Privileged Exec Mode
7. Enter the WRITE command to save your changes in the configuration
file of the stack. The switch displays the confirmation prompt in
Figure 70.
awplus# write
Building configuration ...
[OK]
awplus#
Figure 70. Saving the Priority Values with the WRITE Command
8. Enter the SHOW STACK command to verify the new priority values.
Figure 71 is an example.
MAC address
nnnn:nnnn:nnnn
nnnn:nnnn:nnnn
nnnn:nnnn:nnnn
nnnn:nnnn:nnnn
Figure 71. SHOW STACK Command with New Switch Priority Values
9. To end the management session, enter the EXIT command.
10. Go to Chapter 11, "Cabling Copper and SFP+ Ports" on page 149, to
complete the installation.
x330 Series Installation Guide for Virtual Chassis Stacking
Priority
Status
1
Ready
2
Ready
3
Ready
4
Ready
Normal operations
nnnn:nnnn:nnnn
Role
Active Master
Backup Member
Backup Member
Backup Member
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

X330-10gtxX330-20gtxX330-28gtxX330 series

Table of Contents