Figure 67: Confirmation Prompt For The No Stack Enable Command; Figure 68: Returning To The Privileged Exec Mode; Figure 69: Saving The Changes With The Write Command - Allied Telesis x330 Series Installation Manual

Fanless gigabit layer 3 access switches
Hide thumbs Also See for x330 Series:
Table of Contents

Advertisement

Chapter 8: Verifying the Switch
Warning; This will disable the stacking hardware on member-1.
Are you sure you want to continue? (y/n):
102
6. To. disable the VCStack feature, enter the NO STACK ENABLE
command in this format:
no stack id enable
The ID parameter is the ID number of the switch, displayed on the ID
LED. Replace the parameter with the number displayed by the ID LED.
For example, if the Switch ID LED number is 1, the default value, you
enter the command as follows:
awplus(config)# no stack 1 enable
The confirmation prompt in Figure 67 is displayed.
Figure 67. Confirmation Prompt for the NO STACK ENABLE Command
7. Type Y to disable VCStack on the switch.
8. Enter the EXIT command to return to the Privileged Exec mode. Refer
to Figure 68.
awplus(config)# exit
awplus#
Figure 68. Returning to the Privileged Exec Mode
9. Enter the WRITE command to save your change in the configuration
file. The switch displays the confirmation prompt in Figure 69.
awplus# write
Building configuration ...
[OK]
awplus#
Figure 69. Saving the Changes with the WRITE Command
If this is the first management session, the switch automatically
creates the Default.cfg file in flash memory to store your changes.
10. Enter the REBOOT command to reboot the switch.
11. At the confirmation prompt, type "Y" for yes.
12. Wait one minute for the switch to start the AlliedWare Plus
management software.