Choosing A Site For The Switches - Allied Telesis AT-IE510-28GSX Installation Manual

Industrial ethernet switch
Table of Contents

Advertisement

Chapter 3: Beginning the Installation

Choosing a Site for the Switches

50
Observe these requirements when planning a stack installation.
If you plan to install the switches in an equipment rack, check to be
sure that the rack is safely secured so that it will not tip over.
Devices in a rack should be installed starting at the bottom, with
the heavier devices near the bottom of the rack.
The power outlet should be located near the switches and be
easily accessible.
The site should allow for easy access to the ports on the front of
the switches, so that you can easily connect and disconnect
cables, and view the port LEDs.
The site should allow for adequate air flow around the units and
through the cooling vents on the front and rear panels. (The
ventilation direction is from front to back, with the fan on the back
panel drawing the air out of the unit.)
The site should not expose the switches to moisture or water.
The site should be a dust-free environment.
The site should include dedicated power circuits or power
conditioners to supply reliable electrical power to the network
devices.
Warning
Switches should not be stacked on top of one another on a table or
desktop because that could present a personal safety hazard if you
need to move or replace switches.

Advertisement

Table of Contents
loading

Table of Contents