52
ESI-32 Operation Manual
Amount:
+XXdb = Normalize
where XX is the amount of gain needed to achieve normalization or full
level. Set the amount of gain so that it matches the normalization
reading and press ENTER. The display shows:
FADE
Start:
End:
Size:
We don't want a fade in this example, so simply press ENTER to affect
the gain change. The sample should now be at a higher volume. Note
that you can use the Digital Processing module, 9. Undo to cancel the
effects of Gain Change. Use this feature to further experiment with
different Gain Change settings.
3. Select 1, Taper. Now let' s taper the end of the sample so that it
smoothly fades out instead of ending in a thump. The display
shows:
TAPER
Start:
End:
Size:
Move the start point to about 0.70 seconds and press ENTER. The
display changes to:
Start Amount: 0.00db
End Amount:
Type:
The Start and End amounts on lines two and three are already at the
correct settings. There will be no attenuation at the Start point, tapering
to full attenuation at the End point of the sample.
4. Move the cursor under the Curve Type on line four. Select
Exponential Curve 2, then press ENTER. The sample should now
smoothly fade out instead of ending abruptly. And remember that
Digital Processing, 9. Undo will cancel the effects of Taper. You can
use this feature to further experiment with different Taper settings.
GAIN CHANGE
+00dB
secs
samples
0.00
00000
1.00
44096
1.00
44096
secs samples
0.00
00000
1.00
44096
1.00
44096
TAPER
-96db
Linear