Technical Specifications
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Operating Voltage Range
Current @ 12 V
Read Range*
Green LED Control
Red LED Control
Buzzer Control
Tamper Output
Maximum Cable Distance
to Controller
Environmental Characteristics
Operating Temp. Range
Operating Humidity
Range
Outdoor Usage
* Measured using a Rosslare MIFARE Classic EV1 (ISO card). Read range with
other credential technologies may vary. Range also depends on electrical
environment and proximity to metal.
AYC-x6355 (Rev. B) Installation and User Manual
Regulated
8 to 16 VDC
AYC-H/M6355: Standby: 120 mA, max: 160 mA
AYC-Q6355: Standby: 145 mA, max: 200 mA
AYC-H/M6355: 9 cm (3.5 in.)
AYC-Q6355: 5 cm (2.5 in.)
Dry Contact, N.O.
Dry Contact, N.O.
Dry Contact, N.O.
Open collector, active low, max. sink current
16 mA
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable
-35°C to 66°C (-31°F to 150°F)
0 to 95% (non-condensing)
Weather-resistant, UV-resistant, epoxy-potted,
suitable for indoor and outdoor use
11
Need help?
Do you have a question about the CSN SELECT AYC-6355 Series and is the answer not in the manual?