Introduction Introduction The AY-R12 Proximity Reader is an RFID proximity card reader and is installed when using access control systems. This is a unique product that has a variety of options to control the reader's illumination according to various settings.
Height x Width x Depth 120 x 89 x 21 mm (4.7 x 3.5 x 0.8 in.) Weight 202 g (7.1 oz) * Measured using a Rosslare proximity card or equivalent. Range also depends on electrical environment and proximity to metal. AY-R12 Installation Manual...
”) hole for the cable. 5. Route the interface cable from the reader to the controller. The proximity reader is also mountable using strong epoxy glue. After application, firmly hold the reader in place until the glue dries AY-R12 Installation Manual...
Wiring Instructions Wiring Instructions The AY-R12 is supplied with a 10-wire 45-cm (18”) pigtail, comprising a 6-conductor cable. To connect the reader to the controller: 1. Prepare the reader cable by cutting its jacket back 4.5 cm (1¼”) and strip the wires 1.3 cm (½”).
Page 11
The reader’s cable shield wire should preferably be attached to an earth ground, or a signal ground connection at the panel, or power supply end of he cable. This configuration is best fro shielding the Reader cable from external interference AY-R12 Installation Manual...
Blue with dimming Purple Purple with dimming Yellow Yellow with dimming Light Blue Light Blue with dimming White White with dimming No Illumination 7 colors circularly with dimmer 1 – Not connected; 0 – Connected to the ground AY-R12 Installation Manual...
2. Present the appropriate type of proximity card to the reader. The LED turns green (if set to default) and a short beep is emitted, indicating that the card was read properly by to proximity reader. AY-R12 Installation Manual...
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them. AY-R12 Installation Manual...
Page 15
Tel: +86-755-8610 6842 Fax: +86-755-8610 6101 Rosslare Security Products, Inc. support.cn@rosslaresecurity.com Southlake, TX, USA India Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Rosslare Electronics India Pvt Ltd. Fax: +1-817-305-0069 Tel/Fax: +91-20-40147830 support.na@rosslaresecurity.com Mobile: +91-9975768824 Europe sales.in@rosslaresecurity.com Rosslare Israel Ltd. Rosh HaAyin, Israel...
Need help?
Do you have a question about the AY-R12 and is the answer not in the manual?
Questions and answers