Changing The Programming Code - Rosslare CSN SELECT AYC-6355 Series Installation And User Manual

Smart card readers/controllers (rev. b)
Table of Contents

Advertisement

Reader Functionality
Option 7: Wiegand 56-Bit
In this mode, 7 bytes of card serial number are transmitted in
Wiegand 56-Bit format. No parity bits are added.
AAAA AAAA BBBBBBBB CCCCCCCC DDDDDDDD EEEEEEEE
FFFFFFFF GGGGGGGG
Option 8: Wiegand 64-Bit
In this mode, 8 bytes of card serial number are transmitted in
Wiegand 64-Bit format. No parity bits are added.
AAAA AAAA BBBBBBBB CCCCCCCC DDDDDDDD EEEEEEEE
FFFFFFFF GGGGGGGG HHHHHHHH
6.2.5

Changing the Programming Code

The Programming code cannot be erased, meaning the code 0000
is invalid and does not erase the Programming code.
The factory default 4-digit Programming code is 1234.
To change the Programming code:
1. Enter Programming mode.
2. Press 3 to enter Menu 3.
The left LED turns red.
3. Enter the new 4-digit code you wish to set as
the Programming code.
You hear three beeps.
The system returns to Standby mode.
AYC-x6355 (Rev. B) Installation and User Manual
Green
Red Green
Red
33