Controller Functionality
7.2.3

Secure Mode

The left LED is red.
Only Secure and Master users can access the premises during the
Secured mode.
A Secure user must enter the Primary and Secondary codes to gain
entry. After entering their Primary code, the Door LED flashes green
for 10 seconds, during which the Secondary code must be entered. A
Master user only needs to present the code once to gain entry.
7.2.4

Changing the Modes of Operation

7.2.4.1
Changing from Normal Mode to Secure Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1. Enter the Normal/Secure code.
The left LED flashes red.
2. Press # to confirm the mode change.
The left LED stops flashing.
7.2.4.2
Changing from Secure Mode to Normal Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Secure to Normal mode:
1. Enter the Normal/Secure code.
The left LED flashes green.
2. Press # to confirm the mode change.
The left LED stops flashing.
AYC-x6355 (Rev. B) Installation and User Manual
Red
Green
Red
Red
Red
Green
Green
39