Section 1: Important Notes
February 2018
1.3

Storage Procedures

If your actuator cannot be immediately installed, the following procedures are to be
followed. This will ensure optimum performance from your TEC2 actuator. Failure to
comply with recommended procedures could lead to actuator malfunction and will void
the warranty. For storage procedures exceeding one year, contact your local Emerson
Representative for recommendations.
The TEC2 actuator is a double-sealed and inherently weatherproof unit when shipped
from the factory, providing that all compartment covers and cable entry plugs remain
intact. The actuator should be immediately stored in a clean, dry warehouse, free from
vibration and rapid temperature changes, until it can be installed and energized.
If the actuator must be stored outside, it should be stored off of the ground at an
elevation sufficient to prevent it from being immersed in water or buried in snow,
and covered to prevent damage from site debris.
If not attached to a valve, the preferred orientation is with the motor and electrical
compartment horizontal.
If the actuator is mounted on a valve and the valve stem protrudes from the unit,
a suitable stem protector must be installed to prevent drive-sleeve corrosion.