2.5. Connection of PGM Outputs

ECLIPSE Control Panels Series – PGM capability:
Control panel
Max. PGM outputs
ECLIPSE 8
ECLIPSE 16
ECLIPSE 32
ECLIPSE 99
In the ECLIPSE series alarm panels PGM1, PGM2, PGM3 and PGM4 outputs have a programmable active level. This
allows them to be used to transmit control signals towards external devices (e.g. a block siren input) or to directly
control low-powered external devices (e.g. relays, LED, etc.).
The internal structure of all PGMs (excepting PGM5 in ECLIPSE 32 and ECLIPSE 99) is the same and is shown on
Figure 20 a).
The internal structure of PGM5 in ECLIPSE 32 and ECLIPSE 99, is shown on Figure 20 b).
Important: PGM5 output in ECLIPSE 32 and ECLIPSE 99 control panels are monitored and when are used it is
obligatory to be terminated with 1k resistor to +PGM terminal.
Figure 20 c) shows the connection of the relay and a light-emitting diode to the PGM. The active level of this
connection is low.
a)
Figure 20. Internal structure of PGM output and example for connection of LED
Power output, up to 1A
5
1 (PGM 5), non-monitored
8
1 (PGM 5), non-monitored
32
1 (PGM 5), monitored
99
1 (PGM 5), monitored
PGMx Terminal
Permissible current:
- from +12V - to 10mA
- from GND - to 100 mA
- PGM5 (ECLIPSE 32/99) -
up to 1A
c)
Eclipse 8/16/32/99 Series - Installation Manual
PGM Additional Functionality
PGM 4 - Serial link to TP2000 transmitter
PGM 4 - Fire zone for 24V standard fire base
PGM 4 - Fire zone for 24V standard fire base
b)
For output PGM 5/Bell the
permissible current to GND
is up to 1 A.
27
N.A.
ECLIPSE 32
ECLIPSE 99
PGM5/Bell

Hide quick links: