Eclipse 8/16/32/99 Series - Installation Manual
Using the system bus of the panel
To enter the "Service keyboard" mode with a new keyboard:
-
Connect the keyboard to the system bus and wait the initial initialization to complete.
-
Single press the PRG button (
-
When you finish with the engineer programming, exit to the main screen.
-
Power off the keyboard and disconnect it from the system bus.
To enter the "Service keyboard" mode with a present keyboard in the system configuration:
-
Use one of the other keyboards in the system configuration to delete the unique ID number of the one
selected for service keyboard – enter the keyboard ID address 8xx0, where "xx" is the device number from
02 to 32 (01 is always the PCB of the control panel), and delete the ID number with pressing the "0" button
for 2-3 seconds. It is not necessary to confirm with ENTER.
-
Press the PRG (
-
When you finish with the engineer programming, exit to the main screen.
ATTENTION: If the engineer access is disabled from the manager programming menu the access will
be denied and for the service keyboard!
Adding of service keyboard to the system configuration
Every service keyboard, connected to the panel can be added to the system configuration and to be available for
operation from users. Whether the service keyboard is connected to "Service KBD" connector or to the system bus of
the panel, it can be added to the system configuration as follows:
- Enter the engineer programming menu using the service keyboard.
- Choose a free position for device enrollment (free address)
- Press in sequence the tamper-switch and the
- After the initial initialization is complete the keyboard will ready for additional settings and user operation.

7. UPDATING THE FIRMWARE

Attention: Always use the last actual version of ProsTE Specialized Programming Software
downloaded from the official web page of the manufacturer!
Actual files (SPF) for firmware update are available for download for registered and authorized users only from the
official web page of the manufacturer:
To do a firmware update of your ECLIPSE panel:
1. Download the last actual file for firmware update from the official web page of the manufacturer and save it to your
local computer or laptop.
2. Connect the ECLIPSE panel to the computer – you can use the SERIAL connector with cable ProsTE kit; or a
standard micro USB cable available for the following or higher hardware revisions: Eclipse 8 – HW 2.0, Eclipse 16 –
HW 1.5, Eclipse 32 – HW 2.3, Eclipse 99 – HW 1.4.
3. Run the ProsTE software.
4. Choose ECLIPSE system, according the type of the panel.
5. Read and save the system configuration to your local computer as *.TDF file format.
6. Click with the right button of the mouse and choose from the option list "Firmware update" menu.
7. In the new dialogue window press the Browse button and select the SPF file from your local computer.
8. Press "Update" button in the dialogue window.
9. In the "Communication" dialogue window choose a COM port (to which the panel is physically connected) and press
OK button for confirmation.
10. Wait the firmware update process to complete.
11. Press the Finish button in the dialogue window.
12. Perform a full hardware reset of the panel – see item 3.2.
13. Update the language strings of the panel – start ProsTE at your language, choose "Eclipse Strings" and write them
down to the panel.
14. Write down the saved earlier system configuration (*.TDF file).
).
) button.
http://www.teletek-electronics.com
(ENTER) button of the service keyboard.