Eclipse 8/16/32/99 Series - Installation Manual

2.7. Connecting the Digital Communicator

The telephone line is connected to TIP and RING terminals on the ECLIPSE 8/16/32/99 Control Panel with no
requirements to observe polarity (see Figures 5-8). The telephone device is connected to TIP1 and RING1 terminals on
the ECLIPSE 8/16/32/99 Control Panel with no requirements to observe polarity. The parameters of the digital
communicator are programmed from the engineer. It is not necessary to install additional components if the digital
communicator is not to be used.
You can test the Built-in Digital Communicator working efficiency in menu 4. COMM TEST (ADDRESS 0023) described
in the Engineer programming Manual ECLIPSE 8/16/32/99.
The menus for communicator programming are accessible only from the Engineer of the system (engineer code 7777
by default).
ECLIPSE Control Panels Series – dialer capability:
Control panel
ECLIPSE 8
ECLIPSE 16
ECLIPSE 32
ECLIPSE 99
ATTENTION: Due to differences in PSTNs provided in different countries and territories, Teletek
Electronics cannot provide unconditional assurance of successful operations on every PSTN network
termination point. This may be subject to changes made to the communication facilities or procedures of
each individual telephone service provider.
Additionally, Teletek Electronics' alarm equipment is designed to work with traditional telephone line.
Please, bear in mind that the use of alarm panels over alternative telephone systems like VoIP (Voice over
Internet Protocol) may not be as effective as with traditional telephone line.
If you are experiencing problems with the use of a Teletek Electronics device over PSTN, please contact
us for further assistance.

2.8. ECLIPSE VD Voice Dialer

The ECLIPSE VD voice dialer is an additional module to the ECLIPSE 8/16/32/99 security alarm system. The dialer
serves to transmit alarm event messages to the user, system status check-up and remote control of the system –
arming and disarming, switching on/off of programmable outputs.
Installation of ECLIPSE VD Voice Dialer
Attention: The voice dialer must to be installed ONLY when the mains and back-up power supplies are
switched off and the mini SD memory card is set in the PCB's holder!
1. Switch off the mains and the back-up power supply of
the control panel.
2. Set the spacer support as fix it to the underside of the
control panel PCB – Figure 24-1.
3. Mount the Voice dialer PCB to the VOICE connector
- Figure 24-2.
4. Set the mini SD card in the Eclipse VD holder –
Figure 24-3.
5. Connect the PSTN telephone line to TP and RING
terminals of the control panel without observing the
polarity – Figure 24-4.
6. Switch on the mains and the back-up power supply of
the control panel.
7. Program the options and phone numbers for the
voice dialer according the system organization – Menu 8. COMMUNICATION – 2. VOICE DIALER.
Telephone numbers
2
2
4
4
Protocols
Remote programming
SIA, CID
SIA, CID
SIA, CID
SIA, CID