Teletek electronics ECLIPSE 8 Installation Manual page 23

Alarm control panel
Hide thumbs Also See for ECLIPSE 8:
Table of Contents

Advertisement

Button
17VAC – Power supply from a mains transformer 17V/17VA, fuse 0.63А.
BATT – Terminals for connecting accumulator battery.
+/- AUX – Power supply for detectors with consumption up to 0.75А.
+PGM – Power supply for auxiliary devices with consumption up to 0.75А.
PGM 1 – Programmable output, 100mA, ОС type (open collector).
Z1-Z8 – Zone inputs. Every input is independent full functional zone with freely programmable parameters. Every
additional input must be attached to a zone on the control panel.
COM – Common ground for the zones.
R(red), G(green), Y(yellow), B(black) - System bus interface for connection to control panel.
Tamper – Terminals for Tamper switch. Set a jumper on the terminals if the tamper switch is not used.
F1 – Fuses for PGMs output, 100mA.
Button – Button for enrollment of the module to the system configuration.
17VAC – Power supply from a mains transformer 17V/17VA, fuse 0.63А
BATT - Terminals for connecting accumulator battery
+PGM – Power supply for auxiliary devices with consumption up to 0.75А
PGM 1-8 – Programmable outputs, 100mA, ОС type (open collector). Every output is independent full functional
PGM with freely programmable parameters. Every additional output must be attached to a PGM number on the
control panel.
GND – Common ground for the outputs.
R(red), G(green), Y(yellow), B(black) - System bus interface for connection to control panel.
Tamper – Terminals for Tamper switch.
F1 – Fuse for PGM output, 100mA.
Button – Button for enrollment of the module to the system configuration.
Button
Eclipse 8/16/32/99 Series - Installation Manual
Technical Specifications:
Main power supply
Transformer
Backup power supply
Consumption
Zone inputs
PGM outputs
Operation temperature
Storage temperature
Technical Specifications:
Main power supply
Transformer
Backup power supply
Consumption
PGM outputs, 100mA,
OC type
Operation temperature
Storage temperature
23
230VAC +10%/ -15%
17V/17 VA
12V/7 Ah
Min. 30mA/Max. 750mA
8
1
-20°C ÷ 50°C
-40°C ÷ 60°C
230VAC +10%/ -15%
17V/17 VA
12V/7 Ah
Min. 30mA/Max. 750mA
8
-20°C ÷ 50°C
-40°C ÷ 60°C