Eclipse 8/16/32/99 Series - Installation Manual
Text Menu
5. Options 2
6. Key Switch
7. Auxiliary
8. Name
9. Line Resistance
6. Zone clone
5. Outputs
1. PGM Option (PGM 4)
2. PGMs
XX. PGM
1. Attach
2. Options
3. Areas
4. Activation
5. Act. Parameter 1
6. Act. Parameter 2
7. Deact. Timer
8. Delay
6. Partitions
1. Account Length
2. Double Knock
3. No Move on ARM
4. Postpone Time
5. Areas
XX. Area
01. Exit Time
02. Entry Time
03. Alarm Cycle
04. Account
05. Bell Options
06. ON/OFF Options
07. Panics
08. Name
09. Bell Delay
10. Time Slot
7. Schedules
1. Timeslots
XX. Timeslot
1. Start
Address Menu
Eclipse 8
3.Report Only/
2XX5
6.Chime/
8.Power Up Delay
1.Pulse-Latch/2-3.Key Switch Arming types (Disabled, Full, Stay, Sleep)/
2XX6
2XX7
2XX8
Enter a unique name for the Zone. The menu is accessible via LCD keyboard.
2XX9
2005
3000
Serial Link
3XXY
Programming of outputs options; XX - PGM number; Y - option number.
3XXY
XX: 1-5
3XX0
1.General-Siren Output/
3XX1
2.Polarity Normal-Invert
3XX2
3XX3
Set an activation event type, see the Programming manual for details.
3XX4
3XX5
3XX7
3XX9
4000
4001
4002
4003
4XXY
Programming of areas options; XX - area number; Y - option number.
4XXY
XX: 01
4XX0
Enter the Entry time 1 and Entry time 2 duration 000-255 sec. Default: 015
Note: In Eclipse 32/99 control panels the duration of entry times is limited up to 45
4XX1
seconds, when the requirements of EN50131 for Grade 2 or Grade 3 are applied –
4XX2
Enter the duration of the Alarm cycle for siren outputs 000-255 sec. Default:001
4XX3
Enter a 4/6-digit account number for communication. Default: FFFF
1.Squawk on Arm/2.Squawk on Disarm/
4XX4
3.Clear Bypass on Disarm/
4XX5
1. Enable Police Panic/2.Police Panic Sound type: Audible-Silent/3. Enable Medical
4XX6
Panic/4.Medical Panic Sound type: Audible-Silent/5.Enable Fire Panic
4XX7
4XX8
4XX9
5XXY
5XXY
5XX0
Eclipse 16
3.Report Only/
6.Chime/
7.Pulse Count/
8.Power Up Delay
4.Disarm/5.Normal-Invert/6.Ignore Exit Time
-
-
Menu for viewing the resistance of the line.
-
-
-
XX: 1-8
[DD] [PP] – DD: device number; PP: PGM number;
Note: PGMs 1-5 are fixed and they correspond to the numbers
-
of the hardware outputs of the control panel.
PGM numbers from 06 and higher are freely programmable.
-
1-3
Set Parameters 1 for activation event.
Set Parameters 2 for activation event.
-
-
-
-
1-5 min. Default: 3 min
-
-
-
-
XX: 01-03
Enter exit time duration 000-255 sec. Default: 045
see menu 2. Settings → 15. Standard (address 0096).
5. Fire alarm duration
4.Quick Arm
Enter a unique name for the Area.
-
The menu is accessible via LCD keyboard.
-
-
-
-
-
-
38
Eclipse 32
1.Bell Delay/2.Fire Delay/3.Report Only/
4.Video on Armed/5.Write to log/
6.Chime/7.Pulse Count/
8.Power Up Delay
0.24h Burglary/1.AC Loss/2.Batt Low/
3.Water Leakage/4.Gas Detector/
5.GSM Link Trouble/6.Low Bottled Gas
Level/7.High Temp/8.Low Temp/
9.Loss of Heat
Copying zone options from one to more.
Fire Output
XX: 1-32
1.General-Siren Output/2.Polarity Normal-
Invert/3.Delay sec-min/4.Pulsed Fire
Enabled/5.Deact. Timer sec-min
1-8
Enter time 000-255 sec-min (depends on
the set unit in 2.Options-5). Default:000
Enter time 000-255 sec-min (depends on
the set unit in 2.Options-3). Default:000
[4/6]
Enter time 001-255 min.
Default: 000 (the option is disabled)
Enter time 010-255 min. Default:010
XX: 01-08
1.Squawk on Arm/2.Squawk on Disarm/
3.Alarm memory squawk/
4. 10 min. warning/
5. Fire alarm duration
1.Disarm on Timeslot/
2.Auto Arm: Full-Stay/
3.Clear Bypass on Disarm/4.Quick Arm/
5.Auto Arm on no movement
Enter time 000-255 sec. Default: 000
01-08
Programming of Timeslots;
XX - timeslot number; Y - option.
XX: 01-08
Enter start time for the timeslot.
Eclipse 99
Fire Output
XX: 1-99
1-16
XX: 01-16
01-16
XX: 01-16