Identifying Conditions for Replacing an MPLS Module

If the STATUS LED on the MPLS module turns amber and blinks, use the
command to display the slot status information. The
<slot>
command also displays operational information related to the MPLS module.
Information displayed includes the BlackDiamond switch fabric card state, Network
Processor status, General Purpose Processor status, hardware serial number and type,
and image version and boot settings.
To display the status for slot 1, use the following command:
show slot 1
The status for slot 1 is displayed.
If the
show slot <slot>
down), use the following command to run the diagnostics on the MPLS module and
display the results:
run diagnostics [normal | extended] slot <slot>
To display the MPLS module software diagnostics, you must wait for the DIAG LED to
stop blinking. After the blinking stops, use the following command to display each test
that was run with a Pass/Fail status:
show diagnostics slot <slot>
After you run the diagnostics command, the slot must be reset to reload the
operational code image. Use the
slot <slot>
If the diagnostics fail, replace the MPLS module with another module of the same type.
If one of the network processors fails, the MPLS module continues to operate with
reduced forwarding capacity. As long as the MPLS module is not over subscribed,
network disruption is minimal. The entire card must be rebooted using the
command to recover a halted network processor.
slot
MPLS Module Installation and User Guide
command indicates a processor failure (state will show
reboot {time <date> <time> | cancel}
command to reload the image.
Troubleshooting
show slot
show slot <slot>
reboot
2-13