Installing or Replacing an MPLS Module
e Use a #1 Phillips-head screwdriver to tighten the captive screw on each end of
the module front panel to prevent the module from being dislodged from the
backplane connectors and to ensure satisfactory protection from EMI.
Repeat this procedure for additional modules, if applicable.

Verifying the Module Installation

After you install the MPLS module, verify that the module is working correctly. Check
the LEDs on the front panel of the module and use the command-line interface (CLI)
command to display slot-specific information about the newly
show slot <slot>
installed module.

LED Indicators

When the MPLS module is operating normally, the front-panel LED indicators should
appear as follows:
• STATUS LED indicator: green blinking
• DIAG LED indicator: off

Displaying Slot Status Information

Assuming the MPLS module has no problems, the command
(where
is the number of the slot where you installed the module) displays that
<slot>
ExtremeWare has detected the module and set it to the OPERATIONAL state.
As the module progresses through its initialization, the
displays the GPP subsystem change state to OPERATIONAL, and then each of the
network processors will change state to OPERATIONAL.
When the GPP subsystem completes its initialization cycle and the subsystem
state is OPERATIONAL, use the
check the results of the module power-on self test (POST).
2-8
show slot <slot>
show slot <slot>
show diagnostics {<slot>}
command
command to
MPLS Module Installation and User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blackdiamond 6800 series

Table of Contents