Installing or Replacing an MPLS Module

Identifying Problem Categories

Table 2-1 lists the color states of the MPLS module LEDs and describes their associated
meanings.
Table 2-1: MPLS Module LEDs
LED
Color
STATUS Flashing green
Flashing amber
Off
DIAG
Solid green
Flashing amber
Solid amber
2-10
Indicates
Normal operation
Configuration error (configured
slot type is different than inserted
module type)
Version error (ExtremeWare
version does not recognize
inserted module)
Version error (the MPLS module
image version is not compatible
with the MSM image version)
Hardware error (module failed
diagnostics)
Network processor, GPP down, or
other severe card error (as
detected by network processor
heartbeat protocol)
No power
Normal operation
Diagnostics in progress
Diagnostics failed
Corrective action
No action required.
See "Fixing Configuration
Errors" on page 2-11.
See "Upgrading the Switch
Software Image" on
page 2-11.
See "Upgrading the MPLS
Module Software Image"
on page 2-11.
See "Identifying Conditions for
Replacing an MPLS Module"
on page 2-13.
Reboot slot. If condition
persists, run diagnostics.
See "Fixing Power-Related
Problems" on page 2-12.
No action required.
No action required. When
the LED goes off, use the
show diagnostics
{<slot>} command to display
test status.
See "Identifying Conditions for
Replacing an MPLS Module"
on page 2-13.