Toshiba TS3000 Series Instruction Manual page 95

Hide thumbs Also See for TS3000 Series:
Table of Contents

Advertisement

User parameter setting procedures
*
To designate the slave station number of the TS3100, observe the following
steps. Under [U12] of the USER.PAR (user parameter) file, you can find the
following parameter setting related to the extension input and output.
[U12] Extend I/O setting
{Use/Not Use} (0: Not Use, 1: Use)
{Not Use}
{Not Use}
= 0 28 20 →
= 0 28 20 →
If you wish to use both stations 0 and 1 TR48DIOCN/TR48DIOC module), for
instance, change the underlined bit corresponding to station 0 to "1".
= 1 28 20
= 0 28 20
After saving the parameter file, turn off the controller power and on again.
Then the above parameter becomes effective.
If you wish to use both stations 0 and 1 (i.e., two (2) TR48DIOCN/TR48DIOC
modules), specify as follows and perform the same operation as above to make
the parameter valid.
= 1 28 20
= 1 28 20
Station number and terminator setting
The switches (2 pins) provided on the front upper side of the
TR48DIOCN/TR48DIOC module represent pin 1 (upper) for slave station number
setting and pin 2 (lower) for terminator setting.
Corresponds to station 0.
Corresponds to station 1.
– 95 –