Designation
Output terminal
Signal name
Signal
Function
Signal timing
Cautions
CYC_END (Cycle end)
SYSTEM-35 pin
258
Signal judgment
Output terminal
High
Low
This signal turns on after the stop of 1-cycle automatic
operation only when the CYCLE signal is made valid in the
program execution (RUN) mode and an automatic operation is
executed.
This signal can always be used, irrespective of the master
mode selected by means of the MODE switch.
AUTORUN
(O)
CYCLE
(I)
CYC_END
(O)
1.
This signal turns off when the RUN mode takes effect.
2.
This signal turns on also when the cycle operation has
been stopped by the STOP, BREAK or ALARM signal.
– 75 –
INTERFACE MANUAL
ON
OFF
O
O
STE 80729