Configuring And Enabling Rmon; Example Of Rmon Configuration Commands - Cabletron Systems IA1100 User's Reference Manual

Internet appliance
Hide thumbs Also See for IA1100:
Table of Contents

Advertisement

Chapter 17: RMON Configuration Guide

Configuring and Enabling RMON

By default, RMON is disabled on the IA. To configure and enable RMON on the IA, follow
these steps:
1.
Turn on the Lite, Standard, or Professional RMON groups by entering the rmon set
lite|standard|professional command. You can also configure default control tables
for the Lite, Standard, or Professional RMON groups by including the default-tables
yes parameter.
2.
Enable RMON on specified ports with the rmon set ports command.
3.
Optionally, you can configure control tables for the Lite, Standard, or Professional
RMON groups. For example, if you chose not to create default control tables for the
Lite, Standard, or Professional groups, you can configure control table entries for
specific ports on the IA.
4.
Use the rmon enable command to enable RMON on the IA.

Example of RMON Configuration Commands

The following are examples of the commands to configure and enable RMON on the IA:
(config)# show
ia
Running system configuration:
!
! Last modified from Telnet (10.50.89.88) on 1999-04-05 16:52:28
!
1 : port flow-bridging et.5.(3-8)
!
2 : interface add ip en0 address-netmask 10.50.6.9/16
!
3 : system set contact "usama"
4 : system set location Cabletron Systems, Inc.
5 : system set name "ia"
!
6 : rmon set ports all-ports
7 : rmon set lite default-tables yes
8 : rmon set standard default-tables yes
!
! Set RMON Pro Group with Default Tables ON, cap memory at 4 meg
! Pro: protocolDir, protocolDist, addressMap, al/nl-Matrix, al/nl-Host,
! al/nl-matrixTopN. userHistory, probeConfig.
! Default Tables: one control row per dataSource for protocolDist,
! addressMap, al/nl-Host, al/nl-Matrix.
!
9 : rmon set professional default-tables yes
10 : rmon set memory 4
11 : rmon enable
a. To collect Layer-2 matrix information, port must be configured for flow-bridging mode. By default, ports on the IA
operate in address-bridging mode.
248
a
Internet Appliance User Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ia1200

Table of Contents