TeCHNICAL SPeCIfICATIONS

8.5 electrical characteristics

Power supply
Type
Input voltage
Power consumption
Protection
Micro UPS
These devices are intended to be connected to a "Secondary Circuit Overvoltage Cat-
egory II".
Table 10:
Electrical characteristics

8.6 environmental characteristics

Temperature
Operation
Storage
Humidity
Operation/Storage
Table 11:
Environmental characteristics
8.7 Warranty & approvals
CE
Emission
Interference immunity
Safety
Table 12:
Warranty and approvals
74
Integrated on board, auto ranging
18...32 VDC with 3-pole connector
C6 SMART
C6 SMART CAN
C6 SMART SERIAL
Reverse polarity protection, overvoltage, fuse soldered on
the board
500ms of back up time after 7 years of life at an average
temperature of 45°C
First load: 6 minutes
Rearm time: 90 seconds
0° ... +50°C
-20° ... +60°C
5 to 95% (non-condensing)
Conforms to EN 55022 Information technology equipment
– Radio disturbance characteristics - Limits and methods
of measurement.
Conforms to EN 55024 Information technology equipment
– Immunity characteristics.
Conforms to EN 60950-1 – Information technology equip-
ment – Safety.
19 W / 24V DC
20 W / 24V DC
20 W / 24V DC