Notes on the guarantee ..............6 Chapter 2 General description............7 Presentation ..................8 General technical specifications .............8 Composition and configuration of the systems......11 C6 ECON 8.4” ................11 C6 ECON 10.4” .................11 C6 ECON 12.1” .................11 C6 ECON 15.0” .................12 C6 ECON 17.0” .................12 C6 ECON...................12...
Page 4
Adding an add-on card ..............72 Addition / replacement of Compact Flash modules....74 Chapter 4 Dimensions and drilling templates........77 Dimensions of system C6 ECON 8.4” ........78 Dimensions of system C6 ECON 10.4“ ........81 Dimensions of system C6 ECON 12.1“ ........84 Dimensions of system C6 ECON 15.0” ........87 Dimensions of system C6 ECON 17.0”...
Preliminary operations Chapter 1 Preliminary operations This chapter contains the list of material included in the packing box. • List of material provided • Prior to installation • Notes on the guarantee Karl E. Brinkmann GmbH...
User's manual – C6 ECON List of material provided The following is a list of the material included in the packaging: • System (as ordered configuration) • Adaptor wire for keyboard / mouse (Y-shaped). • Label kit for personalization of front panel keys.
General description Chapter 2 General description This chapter describes the general fea- tures of the systems. • Presentation • General technical specifications • Composition and configuration of the systems. • Front panel. • Display • Rear panel connectors • Expandability configurations. •...
User's manual – C6 ECON Presentation The new C6 ECON family was designed to provide the widest possi- ble scalability in performance and functionality. It based on the CPU “all in one” ASEM 951 for processors of the TRANSMETA families of processors, designed according to a modular structure that always provides the right solution of all automation needs.
Page 9
C6 ECON C6 ECON (Box) Relative humidity maximum 80% without condensation Storage temperature -20°C ÷ +60°C Operative temperature for C6 0°C ÷ 50°C ECON without hard disk with LCD 8.4”, 10.4”, 12.1”, 15.0” and C6 ECON Operative temperature for C6 0°C ÷...
Page 10
User's manual – C6 ECON Weight and dimensions (see chapter 4 on dimensions and drilling template) C6 ECON - 8.4” Frontal panel: 250 x 210 mm. Weight 3.1 Kg C6 ECON - 10.4” Frontal panel: 300 x 245 mm. Weight 4.0 Kg.
General description Composition and configuration of the systems. The C6 ECON systems can be provided with displays of: 8.4”, 10.4”, 12.1”, 15.0” e 17.0”.The C6 ECON systems do not have any display (used in panel or on wall). C6 ECON 8.4”...
User's manual – C6 ECON C6 ECON 15.0” This system is composed of the base module and the display of 15.0”. C6 ECON 15.0” C6 ECON 17.0” This system is composed of the base module and the display of 17.0”.
General description Front panel The front is made of a support anodized aluminium with a polyester film that is resistant to impact and chemicals. The rear body is made of nickel plated steel sheet metal to ensure electromagnetic shielding in order to resolve issues of EMI and RFI. Front panel in aluminium with Touchscreen with...
User's manual – C6 ECON Customization of the function keys On the front panel there are 4 function keys that the user can cus- tomize, in terms of both appearance and function. The default set- tings for the 4 keys are those of the keys F1, F2, F3, and F4 of a standard keyboard.
General description Detail of labels installed standard on the systems Removal/insertion of the membranes of the function keys On the rear of the system there are 4 slots where you can either in- sert or remove the desired label. Slots for insertion / removal of membranes of function keys.
Page 16
User's manual – C6 ECON (sequence 1 of 3) • Insert the label all the way into the pocket. (sequence 2 of 3) Karl E. Brinkmann GmbH...
Page 17
General description inserted labels Detail of fully inserted key customization labels To remove the labels • Grasp the label with a pincer and extract it. Detail of label extraction Karl E. Brinkmann GmbH...
User's manual – C6 ECON Display The front panel of the C6 ECON systems includes a backlit LCD module. The display may be: • 8.4” TFT (2 lamps) with a resolution of 800 x 600 pixels, 262144 colours. • 10.4” LVDS (2 lamps) with a resolution of 800 x 600 pixels, 262144 colours.
General description 8.4” display features The LCD 8.4” module has a maximum resolution of 800x600, active matrix backlit by two fluorescent lamps Brightness is adjusted in the setup. 8.4” display features Dimensions 8.4” Technology LCD-TFT active matrix Visible area 170.4 (A) x 127.8 (L) mm Resolution 800 x 600 Colours...
User's manual – C6 ECON 10.4” LVDS display features The LCD 10.4” LVDS module has a maximum resolution of 800x600, by two fluorescent lamps, brightness is adjusted in the setup. 10.4” display features Dimensions 10.4” Technology LVDSx Visible area 211.2 (A) x 158.4 (L) mm...
General description 12.1” Display features The LCD 12.1” module has a maximum resolution of 800x600, active matrix backlit by two fluorescent lamps Brightness is adjusted in the setup. Display features 12.1” Dimensions 12,1” Technology LCD-TFT active matrix Visible area 246.0 (A) x 184.5 (L) mm Resolution 800 x 600 Colours...
User's manual – C6 ECON 15.0”Display features The LCD 15.0” module has a maximum resolution of 1024x768, ac- tive matrix backlit by four fluorescent lamps Brightness is adjusted in the setup. Display features 15.0” Dimensions 15,0” Technology LCD-TFT active matrix Visible area 304.1 (A) x 228.1 (L) mm...
General description 17.0”Display features The LCD 17.0” module has a maximum resolution of 1280x1024, ac- tive matrix backlit by four fluorescent lamps Brightness is adjusted in the setup. Display features 17.0” Dimensions 17,0” Technology LCD-TFT active matrix Visible area 337.92 (A) x 270.336 (L) mm Resolution 1280 x 1024 Colours...
User's manual – C6 ECON Rear panel connectors Parallel COM3 (optional) UPS connector LAN 1 LAN 2 (optional) COM1 Input 24 V DC Keyboard Earth screw / Mouse USB ports 2.0 detail of connectors of rear panel Reset CPU LED FAIL...
General description Expandability configurations The C6 ECON systems are configured in the factory with two differ- ent types of expansion: • without internal PCI slot detail of inside of C6 ECON without PCI slot • with internal PCI slot Internal...
It can be added in all versions of the C6 ECON systems Detail of UPS module *Backup time depends on machine configuration (type of display, add-on modules, etc.) with fully charged batteries.
Page 27
If the UPS is removed or not used for a long period of time, you will need to charge it completely (this takes about 1.5 hours) by connect- ing the module to an C6 ECON operating system. Karl E. Brinkmann GmbH...
235 x 65 x 50 mm ( L x H x S ) Weight 1200 g. approx. Assembly On back of machine C6 ECON or immediately nearby us- ing the extension cord (optional) of 1 m Connections Connections Shielded cable of approximately 20 cm with connector DB15 on the end Karl E.
General description Ambient Operating +0° ÷ +50°C temperature Electromagnetic Emissions: Standard EN 55022, Class: B compatibility Immunity: Standard EN 55082, Ambient: industrial Pinout Connector DB15 male Pinout Connector DB15 male signal 1 / 2 / 9 Mains power supply - power 7 / 8 / 15 Ground –...
Page 30
User's manual – C6 ECON (sequence 2 of 7) • Position the UPS module on the back of the system as shown in the figure and connect the cable of the UPS to connector DB15 located on the system just below the power supply connector.
Page 31
General description (sequence 4 of 7) (sequence 5 of 7) Karl E. Brinkmann GmbH...
Page 32
User's manual – C6 ECON (sequence 6 of 7) (sequence 7 of 7) • Reconnect the power supply cables to the system and provide power. • The system will now come on. After about 6 seconds the UPS device will become operational.
General description Software installation Driver Linx module installation From the CD provided with the system, select the file setup_dlportIO.exe and run it. The following screens will appear • Press Next to continue installation • Press Yes to continue installation Karl E. Brinkmann GmbH...
Page 34
User's manual – C6 ECON • Press Next to continue installation • Select the folder for installation and press Next to continue. • Select minimal installation (compact) Press Next to continue in- stallation Karl E. Brinkmann GmbH...
Page 35
General description • Press Next to continue installation • Press Next to continue installation • Press Next to continue installation Karl E. Brinkmann GmbH...
User's manual – C6 ECON • Press Finish to complete installation and restart the system. Installation of Driver UPS in Windows environment From the CD provided with the system: • select the file C6 ECONUPS.INF • click with the right mouse button •...
Page 37
General description • From the window, select “ Backup energy source” • From the window, select “ Select”. • From the list "Select manufacturer", select ASEM S.p.A.. From the list "Select Model" select the model OT1200 UPS. The item selected in the field “Port” (default COM1) does not make any dif- ference since it is not used for this purpose.
User's manual – C6 ECON In the configuration panel, it is possible to programme the interven- tion time of the UPS. The minimum time that can be selected is 2 minutes. This means that if the line power supply is not restored within this time, the oper- ating system will run the programme specified in the box below (if in- serted) and will then proceed with system shutdown.
As the line voltage increases, the system goes into the phase of acti- vation and actual power on of the PC, and charging and/or maintain- ing of the UPS. Since the status of the UPS is controlled by the C6 ECON system, via the signal ATX PS_ON, its activation takes place when the C6 ECON system has powered on normally.
Page 40
C6 ECON system, of the UPS module via the Mpson signal, and it will place the machine in standby status (return of line voltage) The return of line voltage places the system back in START status.
General description Deactivation and removal of UPS module If the machine undergoes normal shutdown via the operating system, there are no special procedures for the de-activation of the UPS since it is shut off by the machine to which it is connected. If you want to shut down the machine by means of its power supply, once the UPS has intervened, you will need to deactivate it manually by pressing the button on its side...
Page 42
User's manual – C6 ECON • Remove the two screws of the UPS. (sequence 3 of 4) (sequence 4 of 4) Karl E. Brinkmann GmbH...
General description Battery replacement How long the batteries last depends on a number of factor, but it is mostly due to high temperatures that their life cycles are reduced. During the life cycle of the machine, even if they are quite resistant, they may need to be replaced.
Page 44
User's manual – C6 ECON (sequence 2 of 3) Detail of removed clamps • Disconnect the terminal wires. Be very careful not to cause short circuits, which might damage the unit. (sequence 2 of 3) Karl E. Brinkmann GmbH...
Page 45
General description Detail of removed batteries • Place a new set of clamps in the slots of the UPS to hold the new batteries. (sequence 2 of 3) • Reconnect the batteries to the terminal wires. Carefully note the polarity. Inverted polarity may damage the unit. (sequence 2 of 3) NB: Replace the batteries with the same cells (Cyclon type D 5Ah) Karl E.
Page 46
User's manual – C6 ECON (sequence 2 of 3) • Tighten the clamps and lock the batteries in their seat. (sequence 2 of 3) • Tighten the clamps and lock the batteries in their seat. (sequence 2 of 3) •...
Page 47
General description (sequence 2 of 3) (sequence 2 of 3) • Run a calibration cycle of the batteries (see the paragraph on calibration). Karl E. Brinkmann GmbH...
Cool air intake Cool air intake detail of C6 ECON ventilation holes with internal PCI slot Cool air intake Cool air intake detail of C6 ECON ventilation holes with internal PCI slot...
Page 49
General description Cool air intake Cool air intake detail of C6 ECON ventilation holes without internal PCI slot Karl E. Brinkmann GmbH...
User's manual – C6 ECON Procedure for cleaning fan filter • Remove the anchoring screws of the filter bracket. (sequence 1 of 3) (sequence 1 of 3) • Remove the filter bracket. Karl E. Brinkmann GmbH...
Page 51
General description (sequence 2 of 6) • Remove the filter. (sequence 3 of 3) Karl E. Brinkmann GmbH...
User's manual – C6 ECON System grounding It is absolutely necessary to connect the machine to the ground wire by means of suitable wiring connected to the ground screw. • Remove the ground screw Earth screw (sequence 1 of 2) •...
Page 53
General description (sequence 2 of 6) • Re-tighten the system ground screw. (sequence 2 of 2) Karl E. Brinkmann GmbH...
User's manual – C6 ECON Power supply The system must be powered with at 24V nominal (+18V÷36V), with external cut-off (there is no main switch for the system). • Remove the two-pole connector from the system (sequence 1 of 3) •...
General description (sequence 3 of 3) Mass memory unit In its various versions, the system can optionally be equipped with the following mass memory units: Compact Flash The system can house an externally accessible Compact Flash module. Detail of Compact Flash module Extractable Compact Flash Detail of positioning of Compact Flash...
User's manual – C6 ECON Hard disk The system may optionally house an internal 2.5" hard disk. Detail of positioning of hard disk The hard disk is to be connected by a 44-pole flat cable, which must be inserted in the J8 connector of the CPU 951, which can be ac- cessed by removing the rear cover.
General description Installation of software in various Windows environments • Insert the KEB CD-ROM KEB provided and select the directory \Touschscreen ELO. • Select the sub-directory for the operating system being used. • Run the file Setup.exe. • Select the port COMx to which the operating system has associ- ated the controller.
Page 58
User's manual – C6 ECON Karl E. Brinkmann GmbH...
Installation Chapter 3 Installation • How to start the system • Panel assembly • C6 ECON wall mounting • Access to internal parts Karl E. Brinkmann GmbH...
User's manual – C6 ECON How to start the system Before you power on the system, make sure that all the connections have been properly made. Start-up The system is started by providing 24V DC power. Shutdown To shut down the system normally, you will need to follow the shut- down procedure for the operating system being used (configured so as to support the mode APM –...
Installation Panel assembly The systems may be panel mounted as follows: • Pre-work the housing panel (maximum thickness 4 mm). Comply with the measurements shown in the chapter on dimensions and drilling template. Hook with Hook with fastening screw fastening Housing panel screw Hook with...
User's manual – C6 ECON C6 ECON wall mounting The systems may be panel mounted as follows: • Pre-work the housing panel. Comply with the measurements shown in chapter on dimensions and drilling template. There are 8 fastening points. Fastening may be means of pins,...
Installation Access to internal parts The operations described below must only be performed by qualified personnel. • Shut down the system. • Disconnect the power supply cable from the terminal. • Set the system on a surface. Use care not to damage the front panel.
Page 64
User's manual – C6 ECON (sequence 2 of 3) • Remove the rear cover by pushing it in the opposite direction of the connectors panel as shown in the figure. (sequence 3 of 3) Karl E. Brinkmann GmbH...
Installation Removal of the rear cover (lower part) • Remove the two screws of the rear cover. (sequence 1 of 2) (sequence 2 of 3) • Remove the cover. Karl E. Brinkmann GmbH...
User's manual – C6 ECON (sequence 3 of 3) Riser card removal • Remove the two screws that hold the riser cards to the turrets. (sequence 1 of 3) Karl E. Brinkmann GmbH...
Page 67
Installation (sequence 2 of 3) • Extract the riser card. (sequence 3 of 3) Karl E. Brinkmann GmbH...
User's manual – C6 ECON Removal of hard disk Remove the two screws that hold the hard drive to the cabinet. (sequence 1 of 4) (sequence 2 of 4) Karl E. Brinkmann GmbH...
Page 69
Installation • Remove the two screws that hold the hard disk to the mother- board. (sequence 3 of 4) (sequence 4 of 4) Karl E. Brinkmann GmbH...
Page 70
User's manual – C6 ECON • Disconnect the data flat connector. • Disconnect the power cable. (sequence 3 of 3) Karl E. Brinkmann GmbH...
Installation Ram installation/removal To remove the SODIMM DDR module, you will need to open the sys- tem as previously described. • Expel the SODIMM module by opening the side fastening tabs of the plinth. (sequence 1 of 2) (sequence 2 of 2) For re-insertion, check the correct polarity of the SODIMM module.
User's manual – C6 ECON Adding an add-on card • Remove the screw that holds the covering bracket. (sequence 1 of 4) • Remove the cover bracket. (sequence 2 of 4) Karl E. Brinkmann GmbH...
Page 73
Installation • Completely insert the comb connector in the slot. (sequence 3 of 4) • Secure the card to the cabinet. (sequence 4 of 4) Karl E. Brinkmann GmbH...
User's manual – C6 ECON Addition / replacement of Compact Flash modules The system can house an Compact Flash module accessible from the side. • Remove the protection of the compartment that houses the Compact Flash. (sequence 1 of 5) (sequence 2 of 5) Karl E.
Page 75
Installation • Insert the Compact Flash module in its housing; check for correct polarity. (sequence 3 of 5) • To remove the Compact Flash module, press on the ejector until it comes out. (sequence 4 of 5) • Press the expeller again until the Compact Flash is expelled outwards.
Page 76
User's manual – C6 ECON • Extract the Compact Flash module (sequence 5 of 5) Karl E. Brinkmann GmbH...
Dimensions and drilling templates Chapter 4 Dimensions and drilling templates This chapter describes the dimensions and drilling templates of the systems. Karl E. Brinkmann GmbH...
User's manual – C6 ECON Dimensions of system C6 ECON 8.4” front view Front panel dimensions Hosting panel hole drilling template Karl E. Brinkmann GmbH...
Page 79
Dimensions and drilling templates Side view View from above Karl E. Brinkmann GmbH...
Page 80
User's manual – C6 ECON Rear view Karl E. Brinkmann GmbH...
User's manual – C6 ECON Dimensions of system C6 ECON 12.1“ front view Front panel dimensions Hosting panel hole drilling template Karl E. Brinkmann GmbH...
Page 85
Dimensions and drilling templates Rear view Side view Karl E. Brinkmann GmbH...
Page 86
User's manual – C6 ECON View from above Karl E. Brinkmann GmbH...
Dimensions and drilling templates Dimensions of system C6 ECON 15.0” front view Front panel dimensions Hosting panel hole drilling template Karl E. Brinkmann GmbH...
Page 88
User's manual – C6 ECON side view View from above Karl E. Brinkmann GmbH...
Page 89
Dimensions and drilling templates Rear view Karl E. Brinkmann GmbH...
Dimensions and drilling templates Dimensions of system C6 ECON front view Locked machine dimensions Hanging machine dimensions Rear view Karl E. Brinkmann GmbH...
Page 94
User's manual – C6 ECON View from above Side view Karl E. Brinkmann GmbH...
Connectors Chapter 5 Connectors pin-out This attachment describes the pin-out of the KEB standard connectors in- cluded on the external panel of the sys- tems. • Parallel port connector (DB25F). • Serial port connectors (DB9M, DB15M). • Mouse connector PS/2 (mini-Din).
User's manual – C6 ECON Connector for keyboard/mouse PS/2 The PS/2 keyboard / mouse connector is a female mini-din connec- tor. SIGNAL Keyboard Data Mouse data Ground Power Supply (+ 5 V) Keyboard Clock Mouse Clock Serial interface connector DB9 RS232...
Connectors Serial interface connector DB15 multistandard SIGNAL Transmit Data (RS-232) Receive Data (RS-232) Request To Send (RS-232) Clear To Send (RS-232) Data Set Ready (RS-232) ⎯ Ground Data Terminal Ready (RS-232) Carrier Detect (RS-232) Transmit Data +/Receive Data + (RS-485/RS-422) Transmit Data -/Receive Data - (RS-485/RS-422) Ring Indication (RS-232)