Internal cables and compressed air lines

8
Internal cables and compressed air lines
Internal cables (4 wires 1.25 mm², 2 wires 0.75 mm², 8 wires 0.20 mm²) and air hoses are
used in order to use peripheral devices (e.g. gripper). They are mounted on the upper arm
as shown in the following diagram "Connector for internal cables and compressed air lines".
The pins 1 to 16 are assigned as shown in the following figure. Wiring must be performed
by the user.
The following requirements must be met:
The total current value for the internal wiring harness must be 40 A .
The current-carrying capacity per single conductor (cross-section 0.20 mm²) must not
exceed 3 A or less .
The air pressure for the air hose must not exceed 600 kPA (the inner diameter of the air
hose is Ø 6.5 mm (with air line A)).
1
Air outlet
2
Connector plug for the internal cable feed
through on the casing cover.
3
Connector plug for the internal cable feed-
through on the base
4
Air inlet
-
8
44
Connectors for internal user I/O wiring harness and air line