Amp Hours; Access Codes - Club Car Precedent Maintenance And Service Manual

Electric vehicle with eric charging system gasoline vehicle with kohler ech440 engine
Hide thumbs Also See for Precedent:
Table of Contents

Advertisement

11
Parameters
Anti-Tamper
The anti-tamper setting defines maximum speed if the Anti-Tamper fault is triggered (e.g. controller is disconnected
from the Guardian or Visage system). These speeds can only be activated if the Control Mode option is set to 1
(Guardian/Visage) and are intended to be a deterrent. Factory default setting is 1.
• 0 = OFF; uses controller configured speed (S1 through S4 Fwd Speed, Rev Speed and Speed Cal parameters)
even if the Anti-Tamper fault is triggered
• 1 = 2 mph
• 2 = 0 mph
• 3 = 7 mph
Deterrent Demo
The deterrent demo setting defines maximum speed of Control Mode 3.
• 0 = Controller configured speed (S1 through S4 Fwd Speed, Rev Speed and Speed Cal parameters)
• 1 = 10 mph
• 2 = 7 mph
• 3 = 2 mph
Excel Braking
The excel braking menu item allows the user to turn this function ON or OFF. With it ON, the vehicle maintains the
regen motor braking "feel" of the Excel system. With it OFF, regen motor braking is less aggressive and the vehicle
mimics the "feel" of the IQ system.
For example: A Pedal Up Mode setting of 2 = 150 amps of regen motor braking. Setting Excel Braking to ON
increases regen by 30 amps for a total of 180 amps and a more aggressive braking action.
WalkAway Deterrent
The walkaway deterrent menu item allows the user to turn this function ON or OFF. Walkaway deterrent is triggered by
the High Speed WalkAway fault. With it ON, the reverse buzzer will sound immediately upon the key switch being turned
OFF at speeds above 2 mph. With it OFF, the buzzer will cycle on and off at a higher frequency (7.5 Hz vs. 2.5 Hz).
Battery Type
The battery type menu item is intended to be used with Guardian/Visage so that the type of battery could be determined
and displayed when remotely monitoring vehicles.
Charger Control
Beep Option
The Beep Option controls use of the reverse buzzer to sound a confirmation that charging has started: 0 = OFF, 1
= 1 beep, 2 = 3 beeps. From the factory, the Beep Option will be set to 2.

AMP HOURS

Reset Trip Amp Hours
The reset trip amp hours menu item allows the user to reset counter to zero (0). To reset, set to ON and then
immediately back to OFF. To review or validate, proceed to Amp Hours Display on page 11-13 under the Monitor Menu.

ACCESS CODES

Code A, Code B, and Code C
The code entries are used to place the vehicle in "private speed mode", speed setting code 4. Each vehicle has a
unique code for placing the vehicle in this mode. A vehicle programmed for "private speed mode", speed setting 4,
Page 11-8
2020 Precedent,Villager 2 and 4 Maintenance and Service Manual
CONTROLLER DIAGNOSTIC TOOL (CDT)