Crestron C2N-DVP4DI
Mouse/Serial Control Symbol Programming
Reference Guide – DOC. 6177A
8. Add the Touch In Format symbol to the C2N-DVP4DI. Refer to "Device
Extender Symbols for Touch Input and Output Control" on page 61.
9. Extend the C2N-DVP4DI icon to display the slots.
10. Right click on Slot 1.
Detail View in SIMPL Windows
11. Select C2N-DVP4DI Touch In Format. This adds the icon to slot 1
Mouse/Serial Control.
12. Assign a label to the touchpanel serial join number assigned in VT Pro-e
and to the Slot-01.1 Mouse/Serial Control Crestron Mouse.
13. Compile the program and download to a control system.
14. Establish communication with the touchpanel in Viewport and add the new
device ID to the IP table of the touchpanel.
ADDM 3 134.149.10.142 4
Where:
ADDM is command to add Ethernet devices to the IP table of the
touchpanel.
3 is the CIP ID address of the touchpanel in SIMPL Windows.
134.149.10.142 is the IP address of the control system.
4 is the device ID we added in VT Pro-e.
NOTE: When you set up for this mode, you can still have another mouse device
plugged into the Touchscreen Mouse port and have it control the C2N-DVP4DI, for
example: Micro touch, Elo Touchsystems, Microsoft mouse etc.