Detail View of the C2N-DVP4DI C2I TPS Symbol in SIMPL Windows' Program Manager
The TPS touchpanel symbol defines the signals for Crestron Ethernet and Cresnet
TPS-series touchpanels.
Maximum Touchpanel Digital joins: 4000
Maximum Touchpanel Analog joins: 4000
Maximum Touchpanel Serial joins: 999
Typically, touchscreen layouts are designed in VT Pro-e, where buttons and other
objects such as sliders and gauges are assigned join numbers that correspond to their
function in the application. The join numbers are equivalent to inputs and outputs,
such that when a VT Pro-e project is imported into SIMPL Windows, the previously
assigned join numbers appear automatically as defined signals.
Slot 2: C2I-COM5-232
The C2N-DVP4DI provides four ports that enable and configure RS-232 two-way
serial communication and logic, and one port for serial mouse and RS-232 touch
sensitive devices. To view the ports, expand Slot 2: C2I-COM5-232 is under the
C2N-DVP4DI icon on the lower window of System Views.
Slot 3: C2Net-Device
The C2Net-Device slot enables the C2N-DVP4DI to control up to 252 Cresnet
devices. Each Cresnet device is assigned a unique identifier called a Net ID, which is
a hexadecimal value ranging from 03 to FE.
To view the list of supported devices, expand the control system in the bottom pane
of System Views and double-click the C2Net-Device slot, or right-click and select
Add Item from the submenu. Supported devices include network control modules
and a variety of Crestron wired touchpanels.
To add a device to the system expand the C2Net-Device slot and double-click the
desired Net ID, or right click and select Add Item from the submenu. Then select the
device you want to add. Alternatively, you can drag the device from the Cresnet
Modules folder onto the Net ID.
In Program Manager, the C2Net-Device symbol contains no signals; to program a
controlled Cresnet device, expand the C2Net-Device symbol in Program View. Then
drag the device to Detail View.
Slot 4: C2ENET-1
The C2ENET-1 port enables the C2N-DVP4DI communication through Ethernet to
control up to 252 Ethernet devices. Each Ethernet device is assigned a unique
identifier called an IP ID, which is a hexadecimal value ranging from 03 to FE.
To view the list of supported devices, expand the control system in the bottom pane
of System Views and double-click the C2ENET-1 slot. Supported devices include
Ethernet control modules, PC and Web browser interfaces, and a variety of Crestron
Digital Video Processor
Digital Video Processor: C2N- DVP4DI • 31