Digital Video Processor
Crestron C2N-DVP4DI
Touch Input Control
In SIMPL Windows Program View, right click on slot 1 of the C2N-DVP4DI and
choose Insert Device Extender. Choose C2N-DVP4DI Touch In Format for
inputs and open the symbol in Detail View.
C2N-DVP4DI Touch In Format Symbol
The C2N-DVP4DI Touch In Format device extender symbol is provided for input
programming for the C2N-DVP4DI. This prepares the C2N-DVP4DI for the proper
input string based on the type of pointing device. The two inputs accept touch data in
two different formats: Crestron Mouse Driver and Microsoft Serial Mouse Driver.
All of the inputs are serial.
A string of the given format issued to the C2N-DVP4DI on this symbol controls the
mouse cursor on the C2N-DVP4DI. For example, if you want to control the C2N-
DVP4DI mouse cursor using a CNWM (wireless mouse), you would drop the
CNWM onto a CNRFGWA definition. The data signal of the mouse is then
connected to the <MS_Mouse> input of this device extender.
The <CrestronMouseDriver> input is used if using the Crestron custom serial
mouse driver to control the C2N-DVP4DI. If both the Crestron and Microsoft mice
are connected, and the data comes through simultaneously, they both control the
motion of the cursor.
Currently only the first two inputs of this symbol are active, a serial string connected
to other (undefined) inputs can be safely ignored.
Touch Output Control
In SIMPL Windows, right click on slot 1 of the C2N-DVP4DI and select Insert
Device Extender. Select C2N-DVP4DI Touch Out Format and open the symbol in
Detail View.