7-3-5: Ge Rtp A; 7-3-6: Ge Rtp B, 7-3-7: Ge Rtp C, 7-3-8: Ge Rtp D - Korg M3 Parameter Manual

Music workstation/sampler
Hide thumbs Also See for M3:
Table of Contents

Advertisement

Combination mode
7–3–5: GE RTP A
(GE Real-Time Parameters A)
7–3
–5a
7–3
–5b
In KARMA module A, you can control the GE realtime
parameters independently specified for the KARMA
module.
7–3–5a: GE Number & Name, GE RTC
Select, Tempo
GE Number & Name
GE RTC Select
For more information, please see "7–3–1a: GE Number &
Name, GE RTC Select, Tempo" on page 171.
(Tempo)
For more information, please see " (Tempo)" on page 121.
7–3–5b: GE Real-Time Parameters for
Module Control = A
Module Control = A let you control GE Real-Time
Parameters independently for the corresponding KARMA
Module.
GE RT Parm 1–8, 9–16,17–24, 25–32:
Here you can edit the GE Real-Time Parameters of each
KARMA Module and assign them to KARMA Real-Time
Controls for use with Module Control = Master, A.
GE PARAMETER (GE Real-Time Parameter)
MIN (GE Real-Time Parameter Minimum Value)
MAX (GE Real-Time Parameter Maximum Value)
VALUE (GE Real-Time Parameter Value)
ASSIGN (GE Real-Time Parameter Assign)
[---, SL1...8, SL1s...8s, SW1...8, Dyn1...8]
POL. (GE Real-Time Parameter Polarity)
For more information, please see "GE RT Parm 1–8, 9–16,
17–24, 25–32:" on page 90.
172
7–3
–5
Menu
[1–8, 9–16,17–24, 25–32]
[040.00...300.00, EXT]
[–5000...+5000]
[–5000...+5000]
[–5000...+5000]
[+, –]
▼7–3–5: Menu Command
• 0: Write Combination ☞p.185
• 1: Panel–SW Solo Mode On ☞p.106
• 2: Exclusive Solo ☞p.107
• 3: Copy KARMA Module ☞p.114
• 4: Initialize KARMA Module ☞p.115
• 5: Copy Scene ☞p.115
• 6: Swap Scene ☞p.115
• 7: Capture Random Seed ☞p.116
• 8: Copy from Program ☞p.185
For more information, please see "Combination: Menu
Command" on page 185.
7–3–6: GE RTP B,
7–3–7: GE RTP C,
7–3–8: GE RTP D
(GE Real-Time Parameters B, C, D)
In each KARMA modules B, C, and D, you can control the
GE realtime parameters independently specified for the
KARMA module.
For more information, please see "7–3–5: GE RTP A (GE
Real-Time Parameters A)," above.

Advertisement

Table of Contents
loading

This manual is also suitable for:

M3-88M3-73M3-61M3-m

Table of Contents