COMBI P7–3: KARMA 3
7–3–1: GE RTP M–A
(GE Real-Time Parameters Master A)
7–3
–1a
7–3
–1b
Here you can edit the Real-Time Parameters of the GE for
KARMA Module A. In addition, you can assign GE Real-
Time Parameters to the KARMA Sliders 1–8 or Switches 1–8
so that you can control the phrase or pattern in real-time
while you play.
7–3–1a: GE Number & Name, GE RTC
Select, Tempo
GE Number & Name
This shows the GE selected for the Module.
GE RTC Select
This switches the GE realtime parameter display.
1–8, 9–16, 17–24, 25–32: Respectively display GE realtime
parameters 1–8, 9–16, 17–24, and 25–32.
(Tempo)
For more information, please see " (Tempo)" on page 121.
7–3–1b: GE Real-Time Parameters for
Module Control = Master
Module Control = Master lets you use a single controller
(e.g., Slider 1) to control multiple KARMA Modules
simultaneously, or control individual parameters from
different Modules conveniently at the same time.
GE RT Parm 1–8, 9–16, 17–24, 25–32:
Here you can edit GE parameters and assign GE parameters
to KARMA Real-Time Controls etc. for use with Module
Control = Master.
GE RT PARAM (GE Real-Time Parameter)
MIN (GE Real-Time Parameter Minimum Value)
MAX (GE Real-Time Parameter Maximum Value)
VALUE (GE Real-Time Parameter Value)
ASSIGN (GE Real-Time Parameter Assign)
[---, SL1...8, SL1s...8s, SW1...8, Dyn1...8]
COMBI P7–3: KARMA 3 7–3–1: GE RTP M–A (GE Real-Time Parameters Master A)
7–3
–1
Menu
[1–8, 9–16,17–24, 25–32]
[040.00...300.00, EXT]
[–5000...+5000]
[–5000...+5000]
[–5000...+5000]
POL. (GE Real-Time Parameter Polarity)
For more information, please see "GE RT Parm 1–8, 9–16,
17–24, 25–32:" on page 90.
Note: Normally, the MIN, MAX, VALUE, and POL.
parameters of each module are specified in module A. These
parameter settings are possible if you specify ASSIGN in
Master A.
For example if you want to use Slider1 to control the GE
REALTIME PARAMETER No.1 of module A when Module
Control is set to Master, you would set the Master, A, B, C,
and D's GE REALTIME PARAMETER No.01 ASSIGN to
Slider1. If these are set to ASSIGN, you are able to edit the
MIN, MAX, VALUE, and POL. parameters for Master, A, B,
C, and D.
In this way, you can make GE realtime parameter settings
independently of module A.
▼7–3–1: Menu Command
• 0: Write Combination ☞p.185
• 1: Panel–SW Solo Mode On ☞p.106
• 2: Exclusive Solo ☞p.107
• 3: Copy KARMA Module ☞p.114
• 4: Initialize KARMA Module ☞p.115
• 5: Copy Scene ☞p.115
• 6: Swap Scene ☞p.115
• 7: Capture Random Seed ☞p.116
• 8: Copy from Program ☞p.185
For more information, please see "Combination: Menu
Command" on page 185.
7–3–2: GE RTP M–B,
7–3–3: GE RTP M–C,
7–3–4: GE RTP M–D
(GE Real-Time Parameters Master B, C, D)
Here you can edit the parameters of the GE selected by
Module Control=Master for KARMA modules B, C, and D.
For more information, please see "7–3–1: GE RTP M–A (GE
Real-Time Parameters Master A)," above.
[+, –]