When installing a Smart Array 221 Controller in a system with an existing
array controller, you can either place the new controller at the end of the
controller order or reorder the controllers. Reordering changes the current
drive letter assignments for all drives on the system. To avoid changing
the drive letter assignments, place the new controller at the end of the
controller order and do not create a primary partition on any of the
added disks.
Online Recovery Server Status
This parameter indicates if this Smart Array 221 Controller is able to
participate in Online Recovery and is available only in Advanced Features
(Ctrl+A at the main menu).
Select:
Disabled
Online recovery is disabled
Primary
Smart Array 221 Controller controls the local storage device.
Recovery
Smart Array 221 Controller is able to adopt a storage device from
another system which has had an online recovery event occur.
2.
Review and edit the Controller Characteristics of all other Smart Array
221 Controllers shown in the View or Edit Details screen as described in
Step 1 above.
3.
Press F10 when finished editing the View or Edit Details screen.
4.
Select Step 5: Save and Exit on the Steps in Configuring Your Computer
screen.
5.
Choose Save The Configuration, then restart the computer on the Save
and Exit screen.
6.
Press Enter at the Reboot screen.
7.
Remove the CD or System Configuration diskette and verify that the
server will boot normally without POST errors.
System hardware configuration is complete. Proceed to Chapter 6, "Running the
Array Configuration Utility," to configure drive arrays.