POST Error Messages
continued
Meaning
1775
Slot x Drive Array - ProLiant Storage
System Not Responding SCSI Port (y):
Check storage system power switch and
cables. Turn the system power off while
checking the ProLiant power and cable
connections, then turn the system power
back on to retry.
(RESUME = F1 KEY)
1776
Slot x Drive Array - SCSI Bus Termination
Error – Internal and external drives cannot
both be attached to the same SCSI port.
SCSI port (y): Check cables(RESUME = F1
KEY)
(RESUME = F1 KEY)
1777
Slot x Drive Array - ProLiant Drive Storage
Enclosure Problem Detected (followed by
one or more of the following):
SCSI Port (y): Cooling Fan Malfunction
Detected
SCSI Port (y): Overheated Condition
Detected
SCSI Port (y): Side-Panel must be Closed
to Prevent Overheating
SCSI Port (y): Redundant Power Supply
Malfunction Detected
SCSI Port (y): Wide SCSI Transfer Failed
SCSI Port (y): Interrupt Signal Inoperative
(RESUME = F1 KEY)
1778
Slot x Drive Array resuming Automatic
Data Recovery process.
Writer: Karen Hale Project: Compaq Smart Array 221 Controller User Guide Comments: 388541-001
File Name: N-APPF.DOC Last Saved On: 11/5/98 12:29 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Recommended Action
Turn off power to system. Check external
ProLiant power switch - external drives
must all be powered up before or at the
same time as the main system. Check
cables. If retry does not help, try replacing
the cable, ProLiant firmware, ProLiant
backplane, or the Smart Array 221
Controller.
The internal and external connectors of the
specified SCSI port(s) are both attached to
drives. The SCSI bus is not properly terminated
when internal and external drives are attached
concurrently to the same SCSI bus. The
indicated SCSI bus is disabled until this problem
is resolved.
Turn off the server power and check the
cabling to the specified SCSI port
Check cooling fan operation by placing hand
over fan. Check internal plenum cooling fan
in tower servers or storage systems. If fan is
not operating, check for obstructions and
check all internal connectors. Replace unit
side panel if removed.
If the ProLiant Storage System power LED is
amber instead of green, this indicates a
redundant power supply failure.
Check SCSI cables. If the message indicates
to check SCSI cables, please verify your
cabling against the diagrams in the Smart
Array 221 Controller Installation Guide . If the
routing is correct, replace cables on the
specified port until the POST message is
eliminated.
No action required. This message appears
whenever a controller reset or power cycle
occurs while Automatic Data Recovery is in
progress.
Compaq Smart Array 221 Controller User Guide
F-3
continued

Advertisement

Table of Contents
loading