Options; Immobiliser; Coding New Starting Keys; Deleting Coded Keys - Wacker Neuson ET16 Operator's Manual

Track excavator
Table of Contents

Advertisement

5.13 Options

Immobiliser

A
Fig. 193
0
P
Fig. 194
BA ET16 de* 1.0 * et16b510.fm
A = starting key (blue)
For starting the machine. Scope of delivery includes 2 keys.
B = master key (red)
B

Coding new starting keys

1. Insert master key B in the starter and turn it to position 1 for a
1
maximum five seconds.
2. Remove master key B.
3. Keep master key B at least 50 cm (20 in) away from the starter.
2
4. Within 15 seconds, turn starting keys requiring coding to position 1 for
at least one second.
5. Repeat step 4 if more starting keys require coding.
3
➥ With this the coding of the starting keys is completed.
Coding can be performed for a maximum of 10 starting keys.
Information
The procedure is automatically cancelled if no key requiring coding is
detected by the system within 15 seconds.

Deleting coded keys

Deleting all coded keys is necessary whenever a coded key is lost.
The master key code is not deleted during deletion.
1. Insert master key B in the starter and turn it to position 1 for at least 20
seconds.
2. Code the starting keys.
Information
Store the master key in a safe place. It can only be used for coding new
starting keys.
A new immobilizer must be installed if the master key is lost.