Page 128 of 220 Maintenance
System Status
553-3601-200 Standard 7.00 November 1998
Disable at once? and Disable at idle? . The softkey appears only when
the state is Busy or Wait Idle .
The following maintenance tasks can be performed using the Administration
Terminal, as shown, or Companion Manager. For Companion Manager
instructions, refer to Companion Manager Installation and Operations Guide.
The System Status feature enables you to check the system type and state and
perform system level maintenance actions.
Press ƒ••‚ and enter the Installer password.
1.
From A. Configuration , press * until the display shows
2.
C. Maintenance .
Press ^ . The display shows 1. System Status .
3.
Press ^ . The display shows the product name ( MC ) and
4.
protocol ( PCI ).
5.
Press STATE to see the operational state of the system, described in
Table 34.
6.
Press TYPE at any point to reset the display to show the product name
and protocol, as indicated in step 4.
Press ^ to see the software version and release number.
7.
Press ® to exit, or % to continue in Maintenance
8.
programming.
Note: The system can be disabled if the state is Busy , Failed , Idle ,
or Wait Idle . Pressing DSBL shows Disable at once? on the
display. You can select either YES (the system enters the
Disabling state), or CHANGE (you are asked whether to disable
upon idle; a YES response places the system in the
state).
Wait Idle
Need help?
Do you have a question about the Meridian 1 and is the answer not in the manual?
Questions and answers