Mounting Situation: Interface Plate On The Intermediate Ceiling Mount; Versions; Cutting The Threaded Bolts To Length - Nuvo Navigator Lift 150 Single Installation Instructions Manual

Table of Contents

Advertisement

6
Mounting Threaded Bolts to the Interface Plate
Figure 11: Cutting the threaded bolts for the Single / Duo inter-
face plate on the raw ceiling to length
6.2
Mounting situation: Interface plate on the inter-
mediate ceiling mount

6.2.1 Versions

(See "Figure 11")
The following Figures illustrate the interface plate
shape), for installing the motor arm and motor arm with extension arm
versions.
The steps required for installation on the interface plate
(squared shape) are identical.

6.2.2 Cutting the threaded bolts to length

(See "Figure 11")
If a Single / Duo interface plate
termediate ceiling
, the 6 (Single version) or 12 (Duo version) threaded
2
bolts M16 x 330mm① must be cut to length.
The Single / Duo canopy
to be mounted later is flush with the interme-
3
diate ceiling
and covers the ceiling tube flange.
2
NOTE – Variable threaded bolt length
The necessary length of the threaded bolts M16 x 330mm①
depends on the distance H: from the raw ceiling to the bottom edge
of the intermediate ceiling
Observe the minimum and maximum length of the threaded bolts
M16 x 330mm①.
1.
For a Single canopy
, 150mm, Duo canopy
3
6/12 threaded bolts M16 x 330mm ① to length.
To determine the length LG of the threaded bolts①:
LG=H +135mm (min. 205mm / max. 245mm)
Please contact Nuvo if you have any doubt.
2.
Slightly deburr the 6/12 threaded bolts M16 x 330mm① in order to
ensure maximum thread engagement into the interface plate
3.
Continue the installation as described in Chapter 6.2.3 on Page 28.
27
, Single (round
1
1
is mounted to the raw ceiling with in-
1
.
2
, 150mm, cut the
3
1568911, Edition 2019-04, Version 0