Gateway Specifications - Alarm Lock ArchiTech Series User Manual

Dl-windows for networx v5
Table of Contents

Advertisement

For Gateways, network activity (or bandwidth usage) does NOT occur until you operate DL-Windows software to send
programming to (or receive log data from) physical locks.
Gateways communicate through the network.
Commands (for more information regarding Emergency Commands, see page 42).
AL-IME2 Gateway
NETWORK INTERFACE:
Interface: Ethernet, 10Base-T or 100Base-TX (using RJ-45
jack)
Protocols: TCP/IP, UDP/IP, DHCP
NETWORK RANGE
Gateway / Expander to Locks: Clear field range 500'.
Typical indoor range: Networx 75-175'; ArchiTech Networx:
50-125'.
Gateway / Expander to Expander: Clear field range 500'.
Typical indoor range: 75-175'. Note: Actual range varies
with building construction.
AL RADIO LINK
900 MHz GFSK
50 Channels
10mW power output
POWER
Peak Supply Current: 650mA
Input Voltage: 5 - 6VAC
ENVIRONMENTAL
Operating Temperature: -20˚ to 60˚C (-4˚ to 140˚F)
Storage Temperature: -40˚ to 85˚C (-40˚ to 185˚F)
PHYSICAL
Enclosure Size: 4.5"H x 6.0"W x 1.94"D
Weight: 0.5lbs.
AL-IM2-80211 Gateway
NETWORK INTERFACE
Interface: Ethernet, 10Base-T or 100Base-TX (using RJ-45
jack)
Protocols: TCP/IP, UDP/IP, DHCP
WIRELESS SPECIFICATIONS
Wireless Standards: IEEE 802.11b; 802.11g
Frequency Range: 2.412 - 2.484 GHz
Output Power: 14dBm + 1.5dBm/-1.0dBm
Maximum Receive Level: -10dBm (with PER < 8%)
Data Rates With Automatic Fallback: 54Mbps - 1Mbps
Modulation Techniques: OFDM, DSSS, CCK, DQPSK,
DBPSK, 64 QAM, 16 QAM
SECURITY
SIEEE 802.11 - PSK with AES Encryption 128-bit
Encryption: 128-bit AES Rijndael encryption
NETWORK RANGE
Gateway / Expander to Locks: Clear field range 500'.
Typical indoor range: Networx 75-175'; ArchiTech Networx:
50-125'.
Gateway / Expander to Expander: Clear field range 500'.
Typical indoor range: 75-175'. Note: Actual range varies
8

Gateway Specifications

Gateways will send less than 1000 bytes during these Emergency
Exception: During the Emergency Lockdown Command,
with building construction.
AL RADIO LINK
900 MHz GFSK
50 Channels
10mW power output
POWER
Peak Supply Current: 650mA
Input Voltage: 5 - 6VAC
AVERAGE POWER CONSUMPTION
1300mW (WLAN mode; maximum data rate)
300mW (WLAN mode; idle)
750mW (Ethernet Mode)
ENVIRONMENTAL
Operating Temperature: -20˚ to 60˚C (-4˚ to 140˚F)
Storage Temperature: -40˚ to 85˚C (-40˚ to 185˚F)
PHYSICAL
Enclosure Size: 4.5"H x 6.0"W x 1.94"D
Weight: 0.5lbs.
AL-IME2-POE Gateway
NETWORK INTERFACE
Interface: Ethernet, 10Base-T or 100Base-TX (using RJ-45
jack)
Protocols: TCP/IP, UDP/IP, DHCP
NETWORK RANGE
Gateway / Expander to Locks: Clear field range 500'.
Typical indoor range: Networx 75-175'; ArchiTech Networx
50 -125'.
Gateway / Expander to Expander: Clear field range 500'.
Typical indoor range: 75-175'. Note: Actual range varies
with building construction.
AL RADIO LINK
900 MHz GFSK
50 Channels
10mW power output
POWER
POE Voltage: 48VDC Nominal Class 2
Peak Supply Current: 650mA
Input Voltage: 5 - 6VAC
ENVIRONMENTAL
Operating Temperature: -20˚ to 60˚C (-4˚ to 140˚F)
Storage Temperature: -40˚ to 85˚C (-40˚ to 185˚F)
PHYSICAL
Enclosure Size: 4.5"H x 6.0"W x 1.94"D
Weight: 0.5lbs.