OVERVIEW
The Trilogy Networx
the coverage area of version 2 series Gateways, allowing
control of up to its rated maximum of 63 Networx locks per
Gateway. Installation is simple, as the Expander only re-
quires a connection to an AC outlet.
AL-IME2-EXP Expanders are cost-effective, easier to wire
than conventional Gateways, and feature a simplified 'Plug
and Play' setup where the Networx system automatically
identifies all newly powered Expanders and quickly deter-
mines the best wireless signal pathways. Up to 7 Expanders
can be added to one version 2 series Gateway.
Why use AL-IME2-EXP Expanders?
 Less costly, Expanders can be used in place of addition-
al Gateways
 Does not require network access / Ethernet cables
 Extends wireless lock signal coverage
 Reach otherwise troublesome locks in areas of insuffi-
cient signal strength
 Allows for easier (flexible) positioning of version 2 Gate-
ways
 Allows large area signal coverage with a single network
connection to the Gateway
Note: Expanders are available in two different designs,
the AL-IME2-EXP and the AL-IME2-PIE Plug-In Expander
(identical in operation, the compact AL-IME2-PIE plugs di-
rectly into a standard 120VAC un-switched/uninterruptable
wall outlet).
Version 2
The AL-IME2-EXP " version 2" Expanders (notice the " 2"
in the model name) are the next generation of Networx wire-
less devices.
Because AL-IME2-EXP Expanders only
work with version 2 Gateways, a version 2 Gateway must be
installed and operational in your system for AL-IME2-EXP
Expanders to function (AL-IME2-EXP Expanders cannot
communicate with older "non-version 2" Gateways).
Note: Although the version 2 Gateways and AL-IME2-
EXP Expanders CAN be mixed into an existing system
that includes older "non-version 2" Gateways, at least one
new version 2 Gateway must be up and running before an
AL-IME2-EXP Expander can be used.
IMPORTANT: DL-Windows version 5.4.2 or later is re-
quired to support version 2 Gateways and Expanders.
The AL-IME2-EXP Expander is compatible with Alarm
Lock and Continental Access products. Refer to the docu-
mentation supplied with your software for integration details.
AL-IME2-EXP SPECIFICATIONS
NETWORK RANGE
Gateway/Expander to Locks: Clear field range 500'.
Typical indoor range: Networx 75-175'; ArchiTech Networx:
50-125'. Note: Actual range varies with building con-
struction.
© ALARM LOCK 2018
AL-IME2-EXP Expander extends
AL-IME2-EXP Expander

Installation Instructions

Gateway/Expander to Expander:
Typical indoor range, 75- 175'. Note: Actual range varies
with building construction.
AL RADIO LINK
900 MHz GFSK
50 Channels
10mW power output
- Provided by UL Listed Class 2 Transformer
POWER
Peak Supply Current: 150mA
Input Voltage: 5 - 6VAC
Includes one (1) 6VAC External Power Supply
ENVIRONMENTAL
Operating Temperature: -20˚ to 60˚C (-4˚ to 140˚F)
Storage Temperature: -40˚ to 85˚C (-40˚ to 185˚F)
PHYSICAL
Enclosure Size: 4.5"H x 6.0"W x 1.94"D
Weight: 0.5lbs.
EXPANDER LOCATION GUIDELINES
Once your version 2 Gateway location has been selected,
the next step is to determine where to mount the Expander.
However, the following must be taken into consideration:
 Generally, the Expanders should be within approximately
75 feet (radially) from the Gateway or another Expander
 Expanders should be located within 100 feet (radially) from
the intended wireless lock locations
 Open areas will increase range while concrete building
construction, walls, ceilings and narrow corridors will
decrease range
 ArchiTech series locks generally have shorter range to/
from an Expander
 Select a location that allows access to the power wires
running from the 6VAC power transformer (supplied)
 Expanders should be mounted in elevated areas; however
mounting in a drop ceiling can adversely affect signal
strength
 Preferred mounting position = 6 to 12" below ceiling
 Expanders must be mounted vertically; horizontal "flat"
mounting of the Expander should be specifically avoided
 Although wood and wallboard construction can have little
effect upon signal strength, concrete or brick can reduce
signal strength by up to 35%. Steel-reinforced concrete or
metal lath and plaster can reduce signal strength as much
as 90%!
 Do NOT mount close to electrical wiring or other metal
obstructions such as pipes or conduits
 Installing in computer closets or server rooms can nega-
tively impact signal strength
Helpful Tips
 The AL-NSM Networx Signal Meter and the AL-NSG
Networx Signal Generator can assist with identifying
WI2156BLF 1/18
Clear field range 500'.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Trilogy Networx AL-IME2-EXP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alarm Lock Trilogy Networx AL-IME2-EXP

  • Page 1: Installation Instructions

    (Note: Technical Service is for security professionals only) Publicly traded on NASDAQ Symbol: NSSC © ALARM LOCK 2018 WI2156BLF 1/18 Gateway/Expander to Expander: Clear field range 500'. OVERVIEW Typical indoor range, 75- 175'. Note: Actual range varies ™...
  • Page 2 optimal Gateway locations relative to Expanders and Blue and White ID Cards locks. See WI2092 for complete information. We recommend that when installing any model Gateway, a  The "SIGNAL LEVEL" graph displayed on the front blue-colored "Gateway ID Card" (OI357) be completed, and when installing the AL-IME2-EXP Expander, a white- label of the AL-NSM Networx Signal Meter indi- colored "Expander ID Card"...
  • Page 3 the unit to a wall or other flat surface using the hardware POWER UP provided (see page 4 for printed template). Connect the 6VAC power transformer wires (non-polarized). As shown in Fig. 2, the rear housing includes two mount- Upon power up: ing holes for single-gang (A) and four mounting holes for ●...
  • Page 4 God, or on which In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK's original selling price any serial numbers have been altered, defaced or removed. Seller will not be responsible for any disman-...