5G NR Measurements Using the VSA Software
5G Waveform and EVM Analysis Using VSA Software
128
These following settings use the default values.
— RB Offset(60kHz) = 46 RB
— kSSB(60kHz) = 0
— Periodicity = 5 ms

— Numerology =
The frequency location of an SS Block is not fixed. The default value of 46
RB and kSSB of 0 subcarriers places it in the center of the carrier
bandwidth. This value is calculated based on the 60 kHz numerology as
defined by 3GPP (15 and 30 kHz sub-carrier spacing uses 15 kHz
numerology, 120 and 240 kHz spacing uses 60 kHz numerology.)
120 kHz