Enable/disable other trigger input(s)

This trigger will enable or disable one or more selected trigger inputs.
Select triggers: Select one or more triggers from the pop up menu.
New state:
This is the on/off switch for this trigger input. Please note that in case this trigger
input should become (in)active again, another counter

Reset counters

Select one one or multiple counters that need to be reset.

Send UDP message

This trigger can be used to send a UDP message to external devices.
IP Address: Enter the IP address of the recipient.
Port: Enter the port number for the UDP message.
Message: Enter the UDP message for your recipient.

Send OSC message

This trigger can be used to send an OSC message to external devices.
IP Address: Enter the IP address of the recipient.
Port: Enter the port number for the OSC message.
Address: Enter the address path where the message needs to be sent to within the
recipient application.
Value: Enter the value for OSC message.

Restart

This trigger will perform a restart of the DiGidot C4 controller(s).

Custom

Custom action: This trigger opens a note pad where custom trigger code can be entered. This
option is usually reserved for developers or custom made code.
Action examples: Select an action from the pop up window.

Creating linked triggers

Home > Triggers > Linked triggers
Linked triggers are used to link input triggers to actions with variable values such as linking an analog
input to the master brightness.
On this page it's possible to link the trigger input on the left to an action on the right. Simply select
an input and an action to connect a trigger permanently. The established link is visualized by a