Prepare buffers: Prepares the buffers for the recording process.
to the Start record action.
Start record: Starts recording incoming Art-Net, sACN or DMX Data. Please note that this
action must be a new action and cannot be a sub action following the Prepare buffers
action. Make sure that there is at least 1 sec time between the Prepare buffers and Start
record action.
Stop record: Stops recording.
Play raw scene: Plays the unprocessed record.
Stop raw scene: Stops playing the record.
Save record: Saves the unprocessed record.
Link to another trigger
You can link to other actions that have already been created. This also allows you to trigger an
action list for example.
Select action(s): Select an action from the pop-up menu.
Enable/disable other trigger input(s)
This trigger will enable or disable one or more selected trigger inputs.
Select trigger(s): Select one or more triggers from the pop-up menu.
New state:
This is the on/off switch for this trigger input. Please note that in case this
trigger input should become (in)active again, another counter.
Reset counters
Select one or multiple counters that need to be reset.
Send UDP message
This trigger can be used to send a UDP message to external devices.
IP Address: Enter the IP address of the recipient.
Port: Enter the port number for the UDP message.
Message: Enter the UDP message for your recipient.
Send OSC message
This trigger can be used to send an OSC message to external devices.
IP Address: Enter the IP address of the recipient.
Port: Enter the port number for the OSC message.
Address: Enter the address path where the message needs to be sent to within the recipient
application.
Value: Enter the value for OSC message.
Restart
This trigger will perform a restart of the DiGidot C4 controller(s).
C4 Manual
Version 2.2.0
This action is required prior
48-78
Need help?
Do you have a question about the C4 Extended and is the answer not in the manual?