9
POSITIONING CONTROL
9.2

Positioning Data Setting

9.2.1

Relation between each control and positioning data

The setting requirements and description for the setting items of the positioning data to be
set differ depending on "
The following table shows the positioning data setting items of each control. For operation
details and settings of each control, refer to Section 9.2.2 or the subsequent sections.
Positioning data
Da.1
Da.2
Da.3
Da.4
Da.5
: Setting is required.
- : Setting not required. (Setting value is invalid. If setting, use the defalut value or a value within
the range where no error occurs.)
Control method".
Da.2
Positioning control
Operation pattern
Control method
ACC/DEC time
Command speed
Positioning address/movement amount
9.2.1 Relation between each control and positioning data
Position
Speed
control
control
9.2 Positioning Data Setting