Mitsubishi MELSEC-Q Series User Manual page 77

Positioning module with built-in counter function
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

4
DATA USED FOR POSITIONING CONTROL
Coincidence detection setting
Pr.18
Count value selection at OPR
Pr.19
[Setting contents]
Select whether to use the coincidence detection function.
0: Coincidence detection not request......The coincidence detection function is not
used.
1: Coincidence detection requested......The coincidence detection function is used.
[Precautions]
If setting "1: Coincidence detection requested" while the ring counter function is used,
"Coincidence detection function/ring counter function setting error" (error code: 925)
occurs.
[Setting contents]
Select whether to set OP address to the count value when OPR is completed.
0: OP address not set to count value
Sets OP address stored into "
OPR is completed.
1: OP address set to count value
Does not set OP address stored into "
value" when OPR is completed. ("
Current feed value" to "
Md.1
Current feed value" to "
Md.1
Count value" does not change.)
Md.3
4.2 Parameter List
Count value" when
Md.3
Count
Md.3
4
- 20